Mechanical plant & equipment
O10 Mechanical plant and equipment S10.1 Mechanical plant and equipment,
associated with Residential Uses are designed including pool and spa pumps, pool heaters,
and located so as not have an adverse impact on air-conditioning units and refrigeration units
the visual amenity of the site or surrounding are—
areas. a) where located at ground level, screened
by fencing 1.5m in height or dense
vegetation of at least 1.5m in width
incorporating grouped trees and shrubs
with maximum separation distance of
1m measured from the centre of the
plant; and
b) for Multiple housing Type 2, 3 & 4 are
visually integrated into the line and
plane of the building and roof design
and do not project beyond the height or
width of the building when viewed from
the street and adjoining properties.
Ancillary recreation uses
O11 Ancillary recreation uses, such as outdoor S11.1 If the use involves ancillary use of
tennis courts and half netball courts, do not have outdoor courts including tennis courts, half
an adverse effect on the amenity enjoyed by courts and netball courts—the use complies
users of adjacent or nearby premises nor do they with the requirements in Section 2 of PSP8
cause unreasonable disturbance to local fauna Tennis and Other Courts;
through light emissions by ensuring that all AND
lighting devices are limited to those designed and
S11.2 Any lit tennis court or sports court is
installed to:
located at least 60m from the external wall of
a) minimise light spillage on neighbouring an existing or approved residential dwelling on
premises; an adjacent or nearby lot (as measured from
b) preserve an acceptable degree of lighting the centre line of the court);
amenity at the neighbouring premises; AND
c) provide covers or shading around lights; S11.3 The vertical illumination resulting from
d) direct lights downwards; direct, reflected or other incidental light
e) position lights away from possibly affected emanating from the site does not exceed 8 lux
areas; and when measured at any point 1.5m outside the
boundary and at any level from ground level
f) enable brightness of lights to be adjusted to
upward;
low levels.
AND
S11.4 Any flood lighting is restricted to the
types that give no upward component of light
where mounted horizontally (i.e. a full cut off
luminaire).
O12 Noise originating from the use of the tennis
court does not have a detrimental effect on the
amenity of the area or cause nuisance to S12.1 The court is not used between the
neighbouring residents. hours of 10:00pm and 6:30am the following
day.
Privacy
O13 For Multiple Housing Types 2, 3 and 4, S13.1 Transparent doors and windows are
building and structures are designed and sited to designed and located so they do not directly
ensure the visual privacy of residents of the face transparent doors or windows or the
development and neighbouring properties is private open space areas of other dwelling
protected. units within 10 metres;
14-48