20181085-ASC7 - Part 14 Assessement Criteria (Codes) (1)
Attached to the e-mail Operational Works Application OPW20/0114 - Email 2 of 4 - Civil Plans - Community Titles Scheme Statement - BUP - Part 14 Assessment Benchmarks - 4 Portside Crt, Noosaville.
Attached to the e-mail RE_ Proprietary Products & Compliance with SQUIDEP.eml, inside BP Noosaville - overview of proposed stormwater quality strategy related discussions.msg.
column 1 column 2
Including amendments to 8 June 2018
Specific Outcomes Acceptable solutions (if accepted
The Noosa Plan
development subject to requirements)
Probable solutions (if code assessment)
AND
S21.1 If not in a reticulated water service
O21 Detached houses and Ancillary
area— there is, on the lot, a dam, swimming
dwelling units
pool or water tank accessible for use by the fire
within Bushfire Hazard Areas21 have sufficient
brigade, that contains at least 5,000 litres of
water supply for fire fighting purposes.
water.
Editor’s note:
The 5,000 litres required in S20.1 can be included
within the water required in S21.1 providing it is
accessible for the purpose of fire fighting at all times
and not used for other domestic purposes.
Effluent Disposal
O22 Effluent disposal does not have a No solution provided (no requirement for
significant adverse effect on biodiversity, natural accepted development development)
vegetation or water quality22.
Editor’s note:
O23 Treatment and disposal of wastewater PSP24 – Effluent Disposal details requirements
does not have any detrimental impact on for the design and siting of effluent disposal
Noosa’s major water storage and supply - Lake systems where located outside a sewerage
Macdonald. service area. Compliance with PSP24 will be
considered as part of Council’s assessment of
the plumbing and drainage application.
Environmental Protection
O24 The design, siting and construction of S24.1 Where there is an existing building
buildings and structures minimise the clearing of envelope on the lot that contains vegetation
vegetation and where there is an existing protection measures, clearing of native
preliminary approval that includes vegetation vegetation and building works do not extend
protection measures for the property, the beyond the building envelope, except for the
proposal is consistent with those measures. purposes of a driveway access;
AND
S24.2 Where there is no building envelope
existing on the lot, clearing of native vegetation,
other than for a driveway access does not
extend beyond—
a) 30m of a building or 10m of a structure on
lots greater than 10ha; or
b) 10m of a building or structure on lots 10ha
or less but more than 0.3ha in area; or
c) 3m of a building or structure on lots 0.3ha
or less.
Carparking spaces
O25 Sufficient carparking is provided to S25.1 A minimum of 1 carparking space per
accommodate the number of vehicles likely to dwelling unit is provided on-site.
use the site.
Alternative provisions to QDC
21
Land shown as Bushfire Hazard Area on the overlay maps is designated as bushfire prone area for the purposes of the
Building Regulations 2006. The bushfire hazard area includes land covered by the very high, high and medium bushfire
hazard areas as well as the buffer area category on the overlay maps
22
Council may request additional information on the proposed method of effluent disposal to ensure the nature of the
development is compatible with environmental values. Refer to PSP1 – Information Council May Request.