Including amendments to 8 June 2018
Specific Outcomes Acceptable solutions (if accepted
The Noosa Plan
development subject to requirements)
Probable solutions (if code assessment)
Amenity
O26 Detached houses (including any S26.1 No solution provided (no requirement for
secondary dwelling) and Ancillary dwelling accepted development subject to requirements).
units are located, designed and operated to
avoid significant adverse changes to the light,
air quality, noise, accessibility or other
conditions enjoyed by users of associated,
adjoining or nearby premises; S27.1 A 1.5m landscaped buffer separates any
AND private tennis court or half court from side
O27 Lighting and noise associated with the use property boundaries;
of the Detached house (including any AND
secondary dwelling) and Ancillary dwelling
unit or ancillary recreation uses such as S27.2 Courts are fenced with fencing of 3.6m in
height for a full sized court or 2.4m in height for
outdoor tennis courts and half courts, do not
a half court;
have an adverse impact upon the amenity
enjoyed by users of adjoining or nearby AND
premises nor cause unreasonable disturbance S27.3 Any lit tennis court or sports court is
to local fauna. located at least 60m from the external wall of an
existing or approved residential dwelling on an
adjacent or nearby lot (as measured from the
centre line of the court);
AND
S27.4 For lighting—
a) the vertical illumination resulting from
direct, reflected or other incidental lighting
emanating from the site does not exceed
8 lux when measured at any point 1.5m
outside the boundary and at any level
from ground level upward;
b) all flood lighting is hooded or baffled to
direct lighting downward or is of a type
that gives no upward component of light
when mounted horizontally;
c) all flood lighting is setback a minimum of:
i 6m from the boundary to
any frontage; and
ii 2m to any other boundary; and
d) lighting structures are not more than 8m in
height.
14-66
Detached House Code
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLarge file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.