7 Recommendations
Compliance with the criteria outlined in Section 5 is predicted to be achieved based on the inclusion of the
recommendations outlined below.
7.1 Building Attenuation
The following building attenuation measures are recommended:
a. Function rooms (central) facades (Figure 7) to achieve a sound reduction rating of min. Rw32 for glazing
and min. Rw45 for walls.
b. Function space (southwest) façades (Figure 8) to achieve a sound reduction rating of min. Rw38 for
glazing and min. Rw45 for walls.
Figure 7: Function Room (Central) Façades – Sound Rating
Function room
façades with
sound rating
Figure 8: Function Space (Southwest) Façades – Sound Rating
Function space
all façades have
sound rating
Southwest façade
to be closed during
any use
Site: 3 - 7 Serenity Place, Noosa 19
Reference: 22BRA0079 R01_1