Appendix 2 - Code Assessment
PO11 AO11.1 Not Applicable
Water sensitive urban design principles are applied to achieve The design and construction of a natural channel or The subject site does not contain or adjoin a waterway.
multifunctional design of waterways, wetlands and drainage natural channel rehabilitation works are in accordance
lines that provide for: with the Natural Channel Design Guidelines (Brisbane City
a) stormwater conveyance that uses natural channel design; Council) having regard to local topography, geology and
b) protection of landscape features and ecological important geomorphology.
areas including terrestrial and aquatic habitat;
c) aesthetic and passive recreation values; AO11.2
d) flood management and conveyance of external catchment Landscape features, plant species and habitat types used
stormwater through the development; in stormwater conveyance channels are complementary to
e) landscaping that incorporates local native species; and the local context and natural waterways.
f) bed and bank stability.
AO11.3
Bank and bed stability and planting densities result in a
stable channel over the long term and minimal potential
for pest plant species.
AO11.4
Water Sensitive Design measures are incorporated into
the development, as detailed in the document Water
Sensitive Designs small improvements, new ideas,
concepts and sketch designs for stormwater filtration
systems (Healthy Waterways Water by Design).
AO11.5
Floodplain management is designed in accordance with
the Framework for the Integration of Flood
and Stormwater Management into Open Space published
by Healthy Waterways Water by Design (version current
at the time of development application)
PO12 AO12.1 Not Applicable
Development protects in-stream ecology by maintaining pre- Where run-off from or within the site passes through or The subject site does not contain or adjoin a waterway.
development low flow discharge regimes and maintaining drains to natural channels, waterways or wetlands,
fish passages. development protects in-steam ecology by maintaining
pre-development low flow discharge regimes in
accordance with the frequent flow management objectives
in PSP6 Engineering Design Standards - Roads, drainage
and earthworks
AO12.2
Instream structures such as roads, bridges, culverts, and
other stormwater infrastructure do not cause barriers to
fish passage and facilitate the movement of terrestrial and
aquatic fauna along waterway corridors.
Ref: 204099.T003 Page 5