To accommodate the above service vehicle limitations, a bin pad has been proposed on the southern side of
the aisle to service Lots 71-74. The proposed bin pads are dimensioned to allow room for two bins from each
serviced lot. The pads allow for 0.9 x 0.9m of space per bin. As such, the bin pad servicing the four lots is
designed as 7.2 x 0.9m
Security Gate Inbound HRV/RCV
movements permitted
Bin Pad
Figure 5.1: Internal Service Vehicle Circulation
Regarding the servicing arrangements of the Cooroy golf clubhouse, a loading bay suitable for vehicles up to
the size of a HRV has been provided adjacent to the building.
Swept path analysis for the HRV design vehicle have been performed to demonstrate safe manoeuvring of
the vehicles, as shown in Appendix B.
Site: Lot 2 & 3 Myall Street, Cooroy 16
Reference: 19BRT0357