Minor Change Existing Approval 132001 210319 1 · 132001.210319.1

of 6

Text shows just the words. Original shows the document exactly as it was published.

               4.     ASSESSMENT MANAGER CONDITIONS

                      Environmental Health
               1.     The developer must provide a suitably screen imperviously paved area large enough for all
                      refuse and recycling containers.
                      Building
               2.     An identification survey of the subject site is to be carried out by a Licensed Surveyor and is
                      to be submitted to Council at the time of foundation inspection or immediately thereafter.
                      Such survey shall set out the boundaries of the site and the position of the buildings on the
                      site.
               3.     A verification survey of the building is to be carried out by a Licensed Surveyor and a
                      certificate lodged with Council at completion of the work confirming compliance with the
                      maximum building height above natural surface, required by the provisions of the Planning
                      Scheme.
                      Land Development
               4.     A 3.5m wide vehicular access from the Douglas Street frontage of the site is to be constructed
                      to Council’s design standards. A Development Permit for Operational Works shall be
                      obtained prior to the commencement of any works.
               5.     All redundant vehicular crossings to the site shall be removed and replaced by kerb and
                      channel and footpath paving in accordance with Council’s Standard specifications prior to
                      commencement of the use permitted by this permit.
               6.     All services in footpath area adjacent to the development shall be located prior to designs
                      being completed, and their location being reflected on the design.
               7.     Investigations shall be carried out on the size of the exposed rock near location of access to
                      lot 319. Should the size be excessive than the access may need to be relocated. Details of
                      which shall be provided with operational works application.
                      Car Parking
               8.     Carparking shall be provided within the site as shown on plan DS1 undated as submitted by
                      Will Franklin except as modified herein for at least 6 spaces including a minimum of 6 covered
                      spaces. The carparking area shall be designed to comply with the provisions of AS 2890.1-
                      1993 for user class 1. The double spaces are to be in tandem formation, minimum width of
                      enclosed garages shall be 3.0 metres.
               9.     The carparking area shall be drained and the sealed pavement constructed to access road
                      standards. Plans and specifications for these works shall be submitted in conjunction with
                      an application for a Development Permit for Operational Works.
                      Frontage Works
               10.    A new 1.2 metre wide concrete footpath to Council’s design standards shall be constructed
                      across the Douglas Street frontage of the site and connect to existing footpath in Bryan
                      Street.
                      A Development Permit for Operational Works shall be obtained prior to the commencement
                      of any works. Footpath and property alignment levels maybe obtained from the Works
                      Inspector-Development upon request. The footpath is to be constructed taking care to
                      protect any significant vegetation and underground services.
                      Stormwater Disposal
               11.    Roof and surface water is to be collected on site and is to be discharged through a single
                      underground drain line for each property into existing drainage in Douglas Street.
               12.    The maximum discharge of stormwater drainage allowable to Council's street gutter at any
                      one location is 25 litres/second.



                                                                                                        Page 2 of 6
Document Set ID: 23378051
Version: 2, Version Date: 29/11/2024

Used in these records

About this file

File size
171 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Minor Change Existing Approval 132001 210319 1.pdf · 171 KB (small file)