    1.24a) Certification of water service – Reconfiguring a Lot
               Provide a registered surveyor’s certification that the service point(s)                   Prior to the issue of
               and meter(s) to an existing building, that will remain after                              the Certificate of
               reconfiguration of the lot, will be located wholly within the frontage of                 Completion.
               the lot containing the existing building after the reconfiguration has
               occurred.
               Note: Appropriate Council permits shall be obtained for any
               alteration to internal premises main pipe-work. The developer is
               responsible for all costs associated with the relocation or alteration to
               any existing internal service/s. This includes payment to Unitywater
               for the installation of new or relocation of existing metered water
               services if required.

               Sewerage reticulation – Reconfiguring a Lot (residential and non-
    1.40
               residential)
               a) Provide reticulated sewerage to all lots within the development,                       a) Prior to the issue
                  including a property connection to each lot and connection(s) to                          of the Certificate
                  Unitywater’s existing sewerage network in accordance with                                 of Completion.
                  Unitywater’s Connections Policy and the South East Queensland                          b) Prior to the
                  Water Supply and Sewerage Design and Construction Code.                                   commencement
               b) Compile, submit and obtain approval for engineering drawings                              of the works.
                  and specifications detailing the works required by condition                           c) At the time the
                  1.40a).                                                                                   works are carried
               c) The developer must pay all costs associated with the connection,                          out.
                  inspection and acceptance of the proposed works.
               This condition is imposed under section 99BRDJ of the South-East
               Queensland Water (Distribution and Retail Restructuring) Act 2009.

    1.46       Relocate or re-align sewerage main
               Relocate or re-align the existing 150 mm diameter sewerage main                           Prior to connection
               from the eastern boundary of 41 Picture Point Cres through to the                         to the Unitywater
               existing maintenance hole adjacent to the northwestern boundary of                        network.
               37 Picture Point Cres.
               This condition is imposed under section 99BRDJ of the South-East
               Queensland Water (Distribution and Retail Restructuring) Act 2009.
    1.48       Connect existing dwelling to sewerage
               Connect the existing dwellings on Lot 1 RP2220514 and Lot 3                               Prior to the issue of
               SP265108 to Unitywater’s sewerage network.                                                the Certificate of
               This condition is imposed under section 99BRDJ of the South-East                          Completion.
               Queensland Water (Distribution and Retail Restructuring) Act 2009.
               Advice: Changes to property plumbing will require the Applicant to
               make a plumbing application to the relevant Council.




A&C - Decision Notice Template – Connection Approvals                                                                    Page 5 of 14
Document No: F10716        Revision No: 7        Last Review Date: 10/01/2022 (Minor amend 23/02/2023)     Next Review Date: 10/01/2024

Used in these records

About this file

File size
3.3 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Unity Water Decision Notice Package 2023022875S0 - ACP - 41 Picture Point Cres Noosa Heads -.pdf · 3.3 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.