GENERAL COMMITTEE MEETING 16 JANUARY 2017
Table 1
NOISE LIMITS AT A SENSITIVE RECEPTOR
PERIOD Noise level at noise sensitive place measured as the
adjusted maximum sound pressure level (Lamax, adj,T)
7am – 6pm Background noise level (LAbg,T) plus 5 dB(A)
6pm – 10pm Background noise level plus 5 dB(A)
10pm – 7am Inaudible
NOISE LEVELS AT COMMERCIAL PLACE
PERIOD Noise level at a commercial place measured as the
adjusted maximum sound pressure level (Lamax, adj,T)
7am – 6pm Background noise level (LAbg,T) plus 10 dB(A)
6pm – 10pm Background noise level plus10 dB(A)
10pm – 7am Background noise level plus 8 dB(A)
82. When requested by Council, a Noise Impact Assessment Report (NIAR) showing
monitoring and recording of noise levels must be undertaken to investigate any
complaint (other than a frivolous or vexatious complaint) caused by noise
emissions from operations at the premises.
83. Such monitoring must be undertaken within a reasonable and practicable
timeframe nominated by Council and be performed by a suitably qualified person
in accordance with accepted guidelines and standards. The report is to be
submitted to Council detailing the results of such monitoring and
recommendations for any measures to achieve compliance with limits outlined in
Table 1 of this Decision Notice.
For the purpose of measuring and certifying relevant noise conditions and
reporting (e.g. mechanical plant and equipment, a/c units, motors, refrigeration
equipment, compressors, pumps, rooftop plant and equipment. etc.) a suitably
qualified person is either:
a. a Registered Professional Engineer of Queensland, or
b. an environmental consultant with a minimum of three (3) years current
experience in the field of acoustics.
Rainwater/Detention Tanks
84. In accordance with the Public Health Act 2005, rainwater tanks (including the
detention tank) must be constructed with mosquito proof screens (made from
either brass, copper, aluminium or stainless steel), and constructed with a mesh
size of no more than 1mm, and must be installed in a way that does not
accelerate corrosion. Tanks that contain flap valves must be installed so that
when closed, mosquitoes cannot pass through the valve.
Page 26 of 52