GENERAL COMMITTEE MEETING 16 JANUARY 2017
6pm – 10pm Background noise level plus 5 dB(A)
10pm – 7am Inaudible
NOISE LEVELS AT COMMERCIAL PLACE
PERIOD Noise level at a commercial place measured as the
adjusted maximum sound pressure level (Lamax, adj,T)
7am – 6pm Background noise level (LAbg,T) plus 10 dB(A)
6pm – 10pm Background noise level plus10 dB(A)
10pm – 7am Background noise level plus 8 dB(A)
21. When requested by Noosa Council, a Noise Impact Assessment Report (NIAR)
showing monitoring and recording of noise levels must be undertaken to
investigate any non-vexatious complaint caused by noise emissions from
operations at the premises. Such monitoring must be undertaken and completed
within a reasonable and practicable timeframe as nominated by council and be
performed by a suitably qualified and experienced person.
The NIAR must be submitted to Council detailing the results of such monitoring
and recommendations for any measures to achieve compliance with limits
outlined in Table 1 of this Decision Notice.
22. Measurement of sound pressure levels (adjusted for tonality and impulse) must
be in accordance with Australian Standard AS1055.1 “Acoustics – Description
and measurement of environmental noise – General procedures”.
For the purpose of measuring and certifying relevant noise conditions and
reporting (eg. mechanical plant and equipment, a/c units, motors, refrigeration
equipment, compressors, pumps etc ), a suitably qualified person is either:
a. a Registered Professional Engineer of Queensland, or
b. an environmental consultant with a minimum of 3 years current experience
in the field of acoustics.
Outdoor Lighting Devices
23. Lighting associated with the use must be designed, sited, installed and tested to
comply with Table 2.1 & 2.2 of Australian Standard AS4282-1997 “Control of the
obtrusive effects of outdoor lighting” using a control level of 1.
24. Certification must be submitted to Council from a qualified person which certifies
that all outdoor lighting devices comply with the requirements of this Decision
Notice at the time of commissioning.
For the purpose of certifying outdoor lighting devices for the development, a
qualified person is:
a. a Registered Professional Engineer of Queensland;
b. an environmental or electrical design consultant with a minimum of 3 years
current experience in the field of outdoor lighting.
Odour
25. Odour emissions must be managed in accordance with the Noise and Odour
Assessment Noosa Micro Brewery prepared by GHD Pty Ltd and dated 17
August 2016.