09/1508 - Operational Works - Landscaping. Stormwater, S&E Control, Carparking & Acess, Frontage Works [As Published] · 142009.1508

of 69

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

ASSESSMENT NO:2009/ 0919

J43 Ventilation openings

Design Review

Result

Not applicable.

34.4 Ceiling fans and evaporative coolers

Design Review

Result
Not applicable.
O%-0 Air-conditioning and Ventilating Systems
J5.1 Application of Part
I5.2 Air-conditioning and ventilating systems

Design Review

(a)

4 Lillypilly Court,
KAWANA FOREST.....

An air-conditioning unit or system must-

(i)

(ii)
(iii)

(iv)

(vy)

4551.

be capable of
(A) _ being inactivated when the sole-occupancy unit, building or part of
the building served is not occupied; and
(B) where the air-conditioning unit or system has motorised outside air
and return dampers, close the dampers when the air-conditioning
unit or system is inactivated.
Have any supply and return ductwork insulated and sealed in accordance
with Specification J5.2; and
when serving more than one sole-occupancy unit, zone or area with a unique
thermal] characteristic-
(A) _ thermostatically control the temperature of each sole-occupancy
unit, zone or area; and
(B) not control the temperature by mixing actively heated air and
actively cooled air; and
(C) limit reheating to not more than 7.5K rise in temperature at the
supply air rate for the space served and may be increased or
decreased at the same rate that the supply air rate is respectively
decreased or increased; and
in other than Class 6 restaurant, bar or café or Class 9b building, have an
outdoor air economy cycle-
(A) _ inclimate zone 3, when the system capacity is over 65kWr; and
(B) _inclimate zones 4, 5, 6, 7 and 8 when the system capacity is over
65kWr, have an outside air cycle; and
in a Class 3 building be capable of controlling the temperature of a sole-

occupancy unit at a different temperature during sleeping periods than during
other periods; and

Page No. 10 Phone: (07) 5493 2981
Fax: (07) 5493 3867

Used in these records

About this file

File size
4.9 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

09_1508 - Operational Works - Landscaping. Stormwater, S&E Control, Carparking & Acess, Frontage Works [As Published].pdf · 4.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.