35.    The driveway shall be designed and constructed to Council’s design standards and to grades that prevent
       vehicles from scraping and/or bottoming whilst also allowing pedestrians movements along the footpath
       without any step or level difference. Should any driveways be constructed to grades that do not comply
       with AS/NZS 2890.1-2004, Council will require that the driveway be removed and reconstructed to levels
       that do comply.
       Please note, a step between the driveway and the footpath shall be avoided, as it is preferred to have the
       footpath continue at a constant grade to minimise the potential for pedestrians to trip or fall.
36.    To ensure safety between vehicles exiting the site and vehicles and pedestrians in Bryan Street, the
       driveway and any associated fencing or vegetation near the driveway shall comply with the minimum sight
       line requirements as defined in AS/NZS 2890.1, section 3.2.4. The applicant shall demonstrate
       compliance by illustrating these sight lines on the plans submitted for both Operational Works approval
       and Building Works approval.

37.    All vehicles shall enter and leave the site in a forward direction.
Car Parking
38.    Carparking shall be provided within the site generally as shown on drawing number dwg.1c dated 2
       August 2007 by Macchia Pty Ltd for Taylor Developments, except as modified herein.

39.    A minimum of 4 covered carpark spaces shall be provided on site.

40.    The carparking area shall be designed to comply with the provisions of AS/NZS 2890.1-2004 for user
       class 1A with allowance for vehicles to enter and leave the site in a forward gear and with a minimum
       head clearance (headroom) at any point of 2.2m.

41.    The proposed manoeuvring area adjacent to the garages shall be sign posted to indicate that the area is
       a “Turning Area Only” and that “No Parking is Permitted”. The type and location of the sign shall be clearly
       indicated on any plans submitted for Operational Works approval.

42.    All carparking shall be kept and maintained in a condition fit for use.
Frontage Works
43.    Footpath improvements such as topsoiling, grassing, and tree planting are required to the Bryan Street
       frontage of the site in accordance with Planning Scheme Policy PSP03 Landscaping Plants & Guidelines.
       Grass shall be couch, free of weeds.

44.    A new 1.5m wide concrete path shall be constructed along the Bryan Street frontage of the site in
       accordance with Council’s design standards and to an alignment that protects any significant vegetation
       or any underground services. The path shall join smoothly with the existing path located in the frontage of
       No 30 Bryan Street and extend to the edge of the access driveway to No 16 Bryan Street.

45.    All paths, driveways and parking areas shall be designed and constructed to ensure pedestrian safety
       using non-slip materials, to produce an evenly graded surface finish, and to be in accordance with the
       Disability Discrimination Act 1992 and Australian Standard 1428.1 Design for Access & Mobility.

46.    All redundant vehicular crossings to the site shall be removed and replaced by kerb & channel, footpath
       paving and landscaping such as trees and grasses in accordance with Council’s Standard specifications
       prior to commencement of the use permitted by this permit.
Roof Water & Stormwater Drainage
47.    Roof runoff from any new dwelling shall be directed to a rainwater storage system or tank (minimum
       storage 3000 litres per attached dwelling/unit) that is installed to ensure water from the tank is used for
       external uses (such as watering gardens, irrigation, ornamental ponds, water features, topping-up
       swimming pools, outdoor cleaning, etc) and for use in flushing of toilets internal to the dwelling. All
       rainwater tanks are to be designed and installed in accordance with the Queensland Development Code
       (QDC), Part 25 – Rainwater Tanks, and shall be part of the plumbing application in conjunction with the
       building approval. The location and capacity of the tanks shall be clearly shown on the plans submitted
       for Building Works / Operational Works approval and any overflow shall be directed to the stormwater
       drainage system.

48.    All stormwater drainage (including roof water overflow from the rainwater storage system) shall be
       collected and discharged so there is no net increase in stormwater runoff from the site. Stormwater
       drainage permitted to drain from the site shall be discharged to Council’s kerb & channel street drainage
       system in Bryan Street. Plans of the drainage design shall be prepared by a Registered Professional Civil
       Engineer and submitted to Council prior to obtaining a Development Permit for Operational Works.



AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@bc082f7a\@[email protected]

Used in these records

About this file

File size
56 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Decision Notice - 010.2005.00000813.001 [As Published].pdf · 56 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.