35. The driveway shall be designed and constructed to Council’s design standards and to grades that prevent
vehicles from scraping and/or bottoming whilst also allowing pedestrians movements along the footpath
without any step or level difference. Should any driveways be constructed to grades that do not comply
with AS/NZS 2890.1-2004, Council will require that the driveway be removed and reconstructed to levels
that do comply.
Please note, a step between the driveway and the footpath shall be avoided, as it is preferred to have the
footpath continue at a constant grade to minimise the potential for pedestrians to trip or fall.
36. To ensure safety between vehicles exiting the site and vehicles and pedestrians in Bryan Street, the
driveway and any associated fencing or vegetation near the driveway shall comply with the minimum sight
line requirements as defined in AS/NZS 2890.1, section 3.2.4. The applicant shall demonstrate
compliance by illustrating these sight lines on the plans submitted for both Operational Works approval
and Building Works approval.
37. All vehicles shall enter and leave the site in a forward direction.
Car Parking
38. Carparking shall be provided within the site generally as shown on drawing number dwg.1c dated 2
August 2007 by Macchia Pty Ltd for Taylor Developments, except as modified herein.
39. A minimum of 4 covered carpark spaces shall be provided on site.
40. The carparking area shall be designed to comply with the provisions of AS/NZS 2890.1-2004 for user
class 1A with allowance for vehicles to enter and leave the site in a forward gear and with a minimum
head clearance (headroom) at any point of 2.2m.
41. The proposed manoeuvring area adjacent to the garages shall be sign posted to indicate that the area is
a “Turning Area Only” and that “No Parking is Permitted”. The type and location of the sign shall be clearly
indicated on any plans submitted for Operational Works approval.
42. All carparking shall be kept and maintained in a condition fit for use.
Frontage Works
43. Footpath improvements such as topsoiling, grassing, and tree planting are required to the Bryan Street
frontage of the site in accordance with Planning Scheme Policy PSP03 Landscaping Plants & Guidelines.
Grass shall be couch, free of weeds.
44. A new 1.5m wide concrete path shall be constructed along the Bryan Street frontage of the site in
accordance with Council’s design standards and to an alignment that protects any significant vegetation
or any underground services. The path shall join smoothly with the existing path located in the frontage of
No 30 Bryan Street and extend to the edge of the access driveway to No 16 Bryan Street.
45. All paths, driveways and parking areas shall be designed and constructed to ensure pedestrian safety
using non-slip materials, to produce an evenly graded surface finish, and to be in accordance with the
Disability Discrimination Act 1992 and Australian Standard 1428.1 Design for Access & Mobility.
46. All redundant vehicular crossings to the site shall be removed and replaced by kerb & channel, footpath
paving and landscaping such as trees and grasses in accordance with Council’s Standard specifications
prior to commencement of the use permitted by this permit.
Roof Water & Stormwater Drainage
47. Roof runoff from any new dwelling shall be directed to a rainwater storage system or tank (minimum
storage 3000 litres per attached dwelling/unit) that is installed to ensure water from the tank is used for
external uses (such as watering gardens, irrigation, ornamental ponds, water features, topping-up
swimming pools, outdoor cleaning, etc) and for use in flushing of toilets internal to the dwelling. All
rainwater tanks are to be designed and installed in accordance with the Queensland Development Code
(QDC), Part 25 – Rainwater Tanks, and shall be part of the plumbing application in conjunction with the
building approval. The location and capacity of the tanks shall be clearly shown on the plans submitted
for Building Works / Operational Works approval and any overflow shall be directed to the stormwater
drainage system.
48. All stormwater drainage (including roof water overflow from the rainwater storage system) shall be
collected and discharged so there is no net increase in stormwater runoff from the site. Stormwater
drainage permitted to drain from the site shall be discharged to Council’s kerb & channel street drainage
system in Bryan Street. Plans of the drainage design shall be prepared by a Registered Professional Civil
Engineer and submitted to Council prior to obtaining a Development Permit for Operational Works.
AOP2 c:\docume~1\aop2\locals~1\temp\bcl technologies\easypdf 5\@bcl@bc082f7a\@[email protected]
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Notice - 010.2005.00000813.001 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 56 KB (small file)
- File type
No other editions are linked here.