Appendix B - Geotechnical Assessment · OPW23/0179
Project No. PG-10375 Page | 10 June 2023 Ref: PG-10375, 2023-06-09, LTR VER 1 Michael Cullen – Geotechnical Investigation - Proposed Residence, 128 Gympie Terrace, Noosaville v. Where required, replace the over-excavation with “clean” sand and compact in layers to the design founding level. The founding soils should be compacted to a minimum Density Index of 75% (in accordance with AS 1289 5.6.1). Foundation Design Parameters For footings founded 3m below the ground level, an allowable bearing capacity of 300kPa could be adopted in the indurated sand and 200kPa in the recompacted sand above the indurated sand, following confirmation that a minimum Density Index of 75% is present below the footings. If the exposed sands are disturbed or loosened during the excavation operation, they should be recompacted. Consideration should be given to placing a 50mm thick (minimum) concrete binding layer across the footings, immediately following excavation. Settlement Potential Settlements from a 30kPa raft type foundation system founding 3.0m below existing ground level have been calculated to be in the order of 15mm with anticipated differential settlements of between 25% and 50% of the calculated total settlement for pad footings founded at a similar depth. A modulus of subgrade reaction (k) of 6 to 8 kPa/mm could be adopted for preliminary raft design. The value should be confirmed as raft loads are refined. The settlement will occur as “immediate” settlement as the building loads are applied. Hydrostatic Uplift Forces For a fully tanked basement, hydrostatic uplift forces should be considered in the design. It is recommended hydrostatic uplift forces in groundwater levels to at least RL1.5 to 2.0 be taken into consideration on this site and checked for the Q100 flood condition. 12.1Deep Foundations Where the structure extends beyond the basement, consideration could be given to adopting a deepened foundation system founding into a consistent founding stratum of the main raft. Alternatively, a high level footing system could be adopted, with appropriate ground improvement works, provided the structure can be suitably detailed to tolerate the potential differential settlement between the structures. Where the extent of over-excavation required or the foundation treatment is not considered practical, a deep foundation system could be adopted. Screw piles or possibly driven timber piles could be considered for the support of the proposed structure.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix B - Geotechnical Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.