Appendix B - Geotechnical Assessment · OPW23/0179
Project No. PG-10375 Page | 6 June 2023 Ref: PG-10375, 2023-06-09, LTR VER 1 Michael Cullen – Geotechnical Investigation - Proposed Residence, 128 Gympie Terrace, Noosaville • The stripped surface should be proof rolled using a vibrating roller or a large vibrating plate compactor (say 300kg), to identify areas of weak surficial soils and to compact the upper level material. • The “clean” sands on site will be suitable for re-use as structural fill, provided material is free of organic matter and deleterious material. The silty sand and clays may prove difficult to re-use and should be preferentially disposed of. • Imported fill should be of fair to good quality with a minimum Soaked CBR value of 10%, a maximum Iss=1.0% and a maximum particle size of 75mm, or a clean sand. • All filling should be undertaken in layer thicknesses of approximately 250mm (or as appropriate for the compaction equipment being used). Fill should be compacted to a minimum dry density ratio of 75% Density Index for non- cohesive fill (i.e. sand). • Field density testing should be carried out to check the standard of compaction achieved and the placement moisture content. The frequency and extent of testing should be as per guidelines in AS.3798-2007. 8.0 EARTHQUAKE CONSIDERATIONS The design should consider the effects of an earthquake on the founding soils, as outlined in AS.1170.4-2007, Part 4. Liquefaction occurs as a result of pore pressures increasing and reducing the effective stress to zero with consequent loss of strength. The likelihood of liquefaction for an earthquake can be related to sand density. For an acceleration of 0.08g, the following assessments as shown in Table 2 have been made. TABLE 2 EARTHQUAKE/LIQUEFACTION POTENTIAL Liquefaction Potential Density Index (%) <35 Very Likely (very loose to loose) 35 – 54 Likely (medium dense) >64 Unlikely (medium dense to very dense) Testing results indicated that sands that are likely to undergo liquefaction extended to depths in the order of 2.5m to 3.0m. These materials will require removal, or recompaction, as part of the foundation improvement works and therefore all sands likely to undergo liquefaction will be removed from site during construction. Reference to Section 4.2 in AS1170.4-2007, it is recommended that a site classification of “Class Ce – shallow soil site” be adopted, in accordance with the definitions presented in “Section 4.2 – Class Definitions”.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix B - Geotechnical Assessment.pdfRelated documentApplication case desk ↗
About this file
- File size
- 2.2 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.