If available fuel is allowed to accumulate on the subject site, boardwalks and buildings could be impacted,
potentially leading to structural fire, and the loss of buildings. Landscaping is thus an important determinant
of whether buildings on site may be used as a viable local refuge point in the event of unplanned fire on the
adjacent eastern lot (Discussed in Section 7.5 -
Fire Fighting and Emergency Management Arrangements).
Figure 12 can be used out of a Duty of Care, to assess the tradeoffs between setback and appropriate
construction level, in order to give buildings a "fighting chance" of survival.
Radiant Hat Flux (kw/mZ) Uhly Effects
> 40 -
110 Flame Zone. Even the strongest toughened glass fails.
Latest technology in toughened glass may survive. Most will not. Tim ber ignites without pilot flame. Limit
29 -40 of BAL-40 Construction AS3959 -
2009.
Ignition of timbers witho ut piloted ignition (3 minutes exposure) during the passage of a bu shfire. Most
29 types of to ughened glass could fail. Limit of BAL-29 Construction AS3959 -
2009.
Screened float glass could fail during the passage of a bushfire.Limit of BAL-19 Construction AS3959-
19 2009.
Standard float glass could fail durin!! the passage of a bushfire. Lim it of BAL-12.5 Construction AS3959-
12.5 2009. Som e timbers can ignite with prolonged exposure and with pilot ignition sources leg embers)
Critical conditions. Firefighters not expected to operate in these conditions. Considered life threatening in
under a minute in protective equipment. Fabrics inside a building could ignite spontaneously with long
10 exposures.
7 Likely fatal to unprote cted persons afte r exposure of several minutes.
4.7 Extreme conditions. Finefighter in protective dothine;will feel pain after 60 seconds exposure.
3 Haz ardous conditions. Firefighters expected to 0perate for a short period (10 minutes).
2.1 Unprotected person will feel pain after 1 minute exposure -
non fatal.
i
Table 4. Significance of various RHF levels (Source: NSW RFS, 2006)
Report compiled by Bushfire Risk Reducers for Fulton Trotter Architects, April 2013 Page 19
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application Part 2 of 2 - Application Plans, Bushfire Management Plan and Fire and Evac Plan - OPW13/0463Related documentApplication case desk ↗
About this file
- File size
- 76.1 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.