Skip to the record
Trusted by locals. Built for Noosa.

Council archive · source document

23616 DA - Change a Development Approval [As Published] · 132003.221132.4

of 94

Text shows just the words. Original shows the document exactly as it was published.

Check the original when the exact wording matters.

102. Alterations to lot sizes, number of lots and layout may be required following the issue of
a Development Permit for Operational Works in respect of the internal roadworks
design.

Bikeways/Pedestrian Paths

103. The developer will construct a bikeway link from the existing path already servicing the
Noosa Primary School to the bicycle storage facilities to be included in the proposed
secondary school. This bikeway shall be constructed to the satisfaction of Council.

104. The developer will construct a path along the Beckmans Road frontage of existing Lot
7. The Beckmans Road and new road bikeways should be constructed as indicated on
Eppell Olsen & Partners Drawing No 3966-003 Issue A dated October 2002. The
bikeway on the Beckmans Road frontage may need to be aligned within the open
space area but any alignment would require vegetation retention.

105. The developer will construct a pedestrian/bikeway linkage in the vicinity of proposed
Lot 112 to the northern end of Swanbourne Way in the form of a path and timber bridge
2 metres wide.

106. Internally (that is the area of the development north of Plan 3866-003) the bikeway
network should be as indicated on Plan 6812-39 by PMM Group dated 13/02/03. The
pedestrian and bikeway paths indicated in the open space on the plan will need to have
their alignment and need agreed to in the Open Space Management Pian.

107. The developer will also construct a bikeway within the site that allows connection to the
new road linkage, through the parcel to the east, to Swanboume Way required by this
permit.

108. The developer will be required to pay a contribution towards the construction of the
bikeway link to the Lake Entrance Boulevard Network. The amount of the contribution
shall be $200 per additional lot adjusted for changes to CPI since September 2000.

Sewer

109. A Sewerage Reticulation Master Plan is to be submitted for Council approval prior to
the issue of any further permits.

110. Design for a sewerage system to connect all new lots within the site to Council's
existing sewerage reticulation system shall be to the standards and requirements set
out in Council's Engineering Design Standards. If the design requires the construction
of a pump station and a rising main, the connection point to Council's existing system
will be nominated by the Manager —Land Development.

111. Detailed design drawing and calculations shall be submitted with an application for a
Development Permit for Operational Works in respect of water or sewer works. To
avoid conflict with other underground pipes or services, all existing and proposed
services required by the development shall be shown on the plans.

112. All connections to sewer system shall be carried out either by Council or by a Council
approved Contractor and at no cost to Council. Any connection to a water main shall be
undertaken by Council.

Water

113. AWater Supply Master Plan is to be submitted for Council approval prior to the issue of
any further permits.

-21-

Used in these records

About this file

File size
4.4 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

23616 DA - Change a Development Approval [As Published].pdf · 4.4 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.