                                                 stabilise the soil.


                                       AO13.2                                          The proposed driveway will be
                                                 Vehicular access avoids               included with the dwelling to
                                                 disturbance to the tree               ensure no further clearing is
                                                 protection zone of trees on           required.
                                                 public land.
PO14   Driveways and crossovers      AO14.1 Only one driveway and          Only one driveway is proposed
       are located so they do not           crossover is provided.         for the dwelling.
       impede the safe and efficient
       use of the road network.
                                     AO14.2 Where the premises has         N/A
                                            frontage to more than one
                                            formed and sealed road and the
                                            roads have differing orders in
                                            the Road Hierarchy, the
                                            driveway and cross­over is
                                            provided on the frontage with
                                            the lower order.


                                        AO14.3 For corner lots, driveways              N/A
                                               and crossovers are located
                                               in accordance with Council’s
                                               standard drawings.


                                        AO14.4   If in the Rural zone or Rural         The driveway crossover will be
                                                 Residential zone, the driveway        constructed to provide a
                                                 and cross­over is located to          minimum safe sight distance in
                                                 provide minimum safe sight            accordance with Austroads.
                                                                                       Crossover is to an existing
                                                 distances in accordance with
                                                                                       access easement that services
                                                 Austroads.                            6 allotments.
PO15   Bushfire hazard                  AO15     Within a bushfire hazard area         The proposed dwelling will be
       management:                               where there is no reticulated         connected to a 5,000 litre
                                                                                       rainwater tank for fire fighting
                                                 water supply, the premises
                                                                                       purposes. The 5,000L tank will
       Where located in a Bushfire               has:                                  be fitted with a 50mm camlock
       Hazard Area as shown on                   (a)     an accessible dam,            fitting (fire brigade fitting) to
       the Bushfire Hazard Overlay                       swimming pool or water        ensure the tank is in operational
       Map in Schedule 2 and not in                                                    order.
                                                         tank       available    for
       a water service area, an
       adequate, reliable, safely                        firefighting      purposes
       located and freely accessible                     with an onsite water
       water supply is provided for                      volume of not less than
       fire fighting purposes, which                     5,000 litres; and
       is in addition to day to day
       water supply.                             (b)     a water supply outlet
                                                         pipe 50 millimetres in
                                                         diameter and fitted
                                                         with a standard fire
                                                         brigade fitting
                                                         connected to the
                                                         water supply (other
                                                         than where the water
                                                         supply is in a
                                                         swimming pool or
                                                         dam).
PO16   Flood hazards:                   AO16.1   Where the development is              N/A
                                                 located in the Flood Hazard

                                                                                                        21 | P a g e
Log in to download the original file

Planning Report.pdf · 647 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.