Original source · versioned page text
Planning Report
stabilise the soil.
AO13.2 The proposed driveway will be
Vehicular access avoids included with the dwelling to
disturbance to the tree ensure no further clearing is
protection zone of trees on required.
public land.
PO14 Driveways and crossovers AO14.1 Only one driveway and Only one driveway is proposed
are located so they do not crossover is provided. for the dwelling.
impede the safe and efficient
use of the road network.
AO14.2 Where the premises has N/A
frontage to more than one
formed and sealed road and the
roads have differing orders in
the Road Hierarchy, the
driveway and crossover is
provided on the frontage with
the lower order.
AO14.3 For corner lots, driveways N/A
and crossovers are located
in accordance with Council’s
standard drawings.
AO14.4 If in the Rural zone or Rural The driveway crossover will be
Residential zone, the driveway constructed to provide a
and crossover is located to minimum safe sight distance in
provide minimum safe sight accordance with Austroads.
Crossover is to an existing
distances in accordance with
access easement that services
Austroads. 6 allotments.
PO15 Bushfire hazard AO15 Within a bushfire hazard area The proposed dwelling will be
management: where there is no reticulated connected to a 5,000 litre
rainwater tank for fire fighting
water supply, the premises
purposes. The 5,000L tank will
Where located in a Bushfire has: be fitted with a 50mm camlock
Hazard Area as shown on (a) an accessible dam, fitting (fire brigade fitting) to
the Bushfire Hazard Overlay swimming pool or water ensure the tank is in operational
Map in Schedule 2 and not in order.
tank available for
a water service area, an
adequate, reliable, safely firefighting purposes
located and freely accessible with an onsite water
water supply is provided for volume of not less than
fire fighting purposes, which 5,000 litres; and
is in addition to day to day
water supply. (b) a water supply outlet
pipe 50 millimetres in
diameter and fitted
with a standard fire
brigade fitting
connected to the
water supply (other
than where the water
supply is in a
swimming pool or
dam).
PO16 Flood hazards: AO16.1 Where the development is N/A