               45.    All stormwater quality treatment devices must be maintained in accordance with the Water
                      by Design (2009) Maintaining Vegetated Stormwater Assets (Version 1). The approved
                      Operational Works drawings for the stormwater quality treatment system and detailed life
                      cycle costing of the system must be attached as an addendum to this document. Records of
                      all maintenance activities undertaken must be kept and made available to Council upon
                      request.
                      Roofwater Capture and Reuse
               46.    In conjunction with the development application for Building Works, the hydraulic design of
                      the roofwater drainage system for buildings 5, 6 and 7 is to be piped to the roofwater storage
                      tanks nominated on drawing 33132-SW1.1 Rev E by SCG Consulting Engineers. The
                      roofwater system is to be designed to convey the 1%AEP event of critical duration, with a
                      20% increase in rainfall intensity to account for future climate change.
               47.    A total of 32kL of roofwater storage is to be provided for the development as shown on
                      drawing 33132-SW1.1 Rev E by SCG Consulting. The roofwater is to be plumbed for reuse
                      to the following non-potable fixtures, with the detail provided with the hydraulic design
                      submitted in conjunction with the development application for Building Works:
                      •       Communal landscape irrigation
                      •       Bin wash down
               48.    Certification must be submitted to Council from a qualified person which certifies that the
                      roofwater harvesting tanks and associated reticulation have been installed in accordance
                      with the requirements of this Decision Notice.
                      Services
               49.    Reticulated electricity and telecommunication services must be provided to each unit in
                      accordance with the standards and requirements of the relevant service provider.
               50.    Unless otherwise stipulated by telecommunications legislation at the time of construction, the
                      development must be provided with all necessary conduits, pits and pipes to accommodate
                      the future connection of optic fibre technology telecommunications.
               51.    Certification must be submitted to Council from all relevant service providers (Energex, NBN
                      and Unitywater) which certifies that the development has met the requirements of this
                      Decision Notice and all applicable legislation at the time of construction.
                      Easements
               52.    Unless otherwise agreed in writing by the relevant service provider, any public or third party
                      infrastructure located on the subject site must be placed within an easement registered
                      against the title of the property.
               53.    All easements must be designed in accordance with the planning scheme and granted at no
                      cost to the Grantee. Where the Grantee is Council or a service authority, the easement
                      documentation must be in accordance with the Grantee’s standard easement terms. Draft
                      easement documentation must be submitted to Council for endorsement.
               54.    All works must be kept clear of any existing or proposed easements on the subject land,
                      unless agreed otherwise in writing by the Grantee.
                      Earthworks and Retaining Walls
               55.    All earthworks and associated structures/batters must be contained entirely within the subject
                      site unless written permission from the respective landowner(s) is provided to Council.
               56.    All earthworks must be undertaken in accordance with the provisions of Australian Standard
                      AS3798: Guidelines on Earthworks for Commercial and Residential Developments, Building
                      Code requirements and Noosa Plan 2020.




                                                                                                      Page 9 of 30
Document Set ID: 23245480
Version: 4, Version Date: 17/09/2024

Used in these records

About this file

File size
270 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Minor Change Existing Approval MCU23_0094 01 [AS PUBLISHED].pdf · 270 KB (small file)