Performance Criteria Acceptable Solution Comments
Design, construction and safety – all prescribed tidal work
in the construction of b) if a relevant planning scheme standard the works. The location of the
the work; or is more stringent than the standard control is shown on the
b) disturbance to the mentioned in paragraph (a) – the proposed plans.
sediment on the bed relevant planning scheme standard, to
and banks of the tidal the extent it is more stringent than the
water; or standard mentioned in paragraph (a).
c) exposure to acid
sulphate soils.
12.7 Prescribed tidal works The design and construction of the Compliant.
are designed and prescribed tidal works is consistent with
constructed in a way to the following standards:- The proposed works will be
ensure it is safe for persons a) subject to paragraph (d), each consistent with the relevant
using the works. Australian Standard relevant to the Australian Standards. This is
design or construction of structures, incorporated in the engineer’s
the materials that should be used, for certificate.
structures, to the extend the The proposed works will be
requirements stated in the Standard suitable for each required
are directed at ensuring any surface of purpose and this is certified by
prescribed tidal works on which may the engineer’s certificate.
stand or walk is:- on which a person
may stand or walk is:-
(i) not slippery; and
(ii) does not have any feature that
may cause the person to trip or fall;
b) subject to paragraph (d), any part of
prescribed tidal works that is unsafe for
persons standing or walking on the
work is surrounded by adequate
barriers to deter persons from entering
the part;
c) subject to paragraph (d), each
Australian Standard relevant to the
design or construction of structures, to
the extent the requirements stated the
Standard are directed at ensuring
prescribed tidal works provide safety
ladders or other design features for the
safety of a person who falls off the
works into water;
d) if a relevant planning scheme standard
is more stringent than the standard
mentioned in paragraph (a), (b) or (c) –
the relevant planning scheme
standard, to the extent it is more
stringent than the standard mentioned
in paragraph (a), (b) or (c).
Development Assessment Report Page 23 of 42
Operational Works
37 Mossman Court, Noosa Heads 4567
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.