05. Hales - Planning Report
Attached to the e-mail Operational Works Application OPW20/0117 - 37 Mossman Crt Noosa Heads.
PROJECT URBAN – 20153 13 Jul 2020
Performance Criteria Acceptable Solution Comments
Design, construction and safety – all prescribed tidal work
relevant planning scheme standard, to
the extent it is more stringent than the
standard mentioned in paragraph (a)
or (b).
Performance Criteria Acceptable Solution Comments
Design, construction and safety – boat ramps and slip ways for private purpose
13.1 Prescribed tidal works (s 5(2) outcome) Not applicable.
that are a boat ramp or slip
way for a private purpose is The design and construction of the boat The proposal is not a boat ramp
designed and constructed in ramp or slip way is consistent with the or slip way.
a way to ensure it is following standards:-
structurally sound while also a) subject to paragraph (c), the walls at
ensuring the safe movement the edge of a boat ramp or slip way
of vehicles or persons penetrate into the earth at least
between the boat ramp or 600mm below the surface of the land
slipway and the surface of the on which the boat ramp or slip way is
land on which the boat ramp located;
or slip way is located. b) subject to paragraph (c), the surface of
a boat ramp or slip way is not more
than 200mm above the surface of the
land on which is it located;
c) if a relevant planning scheme standard
is more stringent than the standard
mentioned in paragraph (a) – the
relevant planning scheme standard, to
the extent it is more stringent than the
standard mentioned in paragraph (a)
or (b).
13.2 Prescribed tidal works The design and construction of the boat Not applicable.
that are a boat ramp or slip ramp or slip way is consistent with the
way for a private purpose are following standards:- The proposal is not a boat ramp
designed and constructed in a) subject to paragraph (d), the upper or slip way.
a way to ensure the safe surface of a boat ramp or slip way has
movement of vehicles or a width of:-
persons over the boat ramp (i) for a boat ramp or slipway with
or slip way. vehicle access – no less than
3.6m; or
(ii) for a boat ramp or slipway
without vehicle access – no
less than 3.0m;
b) subject to paragraph (d), the whole
upper surface of a boat ramp or slip
way is treated to prevent it from
becoming slippery by using any of the
following methods:-
Development Assessment Report Page 25 of 42
Operational Works
37 Mossman Court, Noosa Heads 4567