Original PDF page 110, section 1. The text section number identifies this passage in the reader.

                                                               5   EWP operator’s certification (licence) will be sighted and        the workplace
                                                                                                                                     NSW & QLD &
                                                                                                                                                             HSO at Induction
                                                                   copied (where there is a facility) at induction.
                                                                                                                                     SA 2011
                                                               6   Operators will wear a full body harness connected to the         Managing the            Site Manager /
                                                                   anchor point within the basket whilst in operation of a EWP       risk of falls in        Subcontractor
                                                                   Boom Lift and to be licensed to operate where the boom            the workplace
                                                                   length is 11m or more.                                            TAS & NT 2012
                                                                                                                                    Plant VIC 1995
                                                               5   Safe approach distances will be determined by plant operators
                                                                   and/or the Site Supervisor using the COP: Working Near
                                                                   Exposed Live Parts and Electrical Safety Act 2002 (or the
                                                                   relevant state legislation / codes of practice / Australian
                                                                   Standards) prior to any work commencing near overhead
                                                                   power lines.
                                                               5   No worker, equipment or EWP will be required to enter the
                                                                   exclusion zone around power lines.
                                                               5   Prior to use operators are to obtain relevant working at
                                                                   heights permits.



☒   Environmental Impacts

                    -   Dust Emissions
                                               B   3    H          On site watering equipment to be available to dampen down        Env. Protection    D3   Site Manager / HSE
     Air Quality                                              5
☒                   -   Complaints from
                        neighbours                      17         work areas and trafficable areas.                                 Act 1994
                                                                                                                                    Env Protection     M9
                    -   Infringement Notices                   5   Reduce speed limit for plant and site vehicles.
                                                                                                                                     (Air) Policy
                        and fines                                  Plant generating dust to be fitted with appropriate water or      2004 TAS
                                                               4
                                                                   collection control.                                              Protection of
                                                               5   Visually monitor dust and emissions generated weekly.             the
                                                                                                                                     environment
                                                                                                                                     operations
                                                                                                                                     (clean air)
                                                                   Limit dust generating activities during windy or storm            regulation 2010
                                                               5                                                                     NSW
                                                                   conditions.
                                                                                                                                    Env Protection
                                                                                                                                     (Air) Policy
                                                                                                                                     2008 QLD
                    -   Short term noise and
                                               B   3    H      5   Keep neighbours informed of any expected noisy events or         Env Protection     D3   Site Manager / HSE
     Noise and
☒    Vibration
                        vibration from plant
                        activities on site              17         changes to schedule.                                              (Noise) Policy
                                                                                                                                     2008 QLD           M9
                    -                                          2   Engage an electric tower crane.
                        Complaints from                                                                                             AS/NZ
                        neighbours                             5   Operation of plant and deliveries to occur between 7.00am         2436:1981
                    -   Work outside                               to 5.30pm Monday to Saturday, except where prior approval         "Guide to Noise
                        approved site                                                                                                Control on
                                                                   has been obtained (e.g. from local council).
                        operating hours                                                                                              Construction,
                                                               5   Plant and equipment on site will not exceed the adjusted          Maintenance
                                                                   noise level by +10dB. Periodic monitoring may be undertaken       and Demolition
                                                                   as required by Site Manager.                                      sites.”

                                                       WHS Management Plan – Appendix 1 – Project Risk Assessment
                                                                                                                                                                              Page 26

Used in these records

About this file

File size
16.2 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

WHSMP.pdf · 16.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.