3 Barricading will be used where the risk of other personnel Safe Site Manager /
entering the area is considered “HIGH.” This barricading is to guarding of
machinery Subcontractor / HSO
isolate the work area where the explosive power tool is being and plant
used. 2009 WA
6 Operators and all personnel in the direct vicinity of explosive Managing Site Manager /
power tool activities will wear personal protective equipment the risks of
plant in the
Subcontractor / HSO
including: safety helmets, eye protection, hearing protection
workplace
and protective footwear. 2012 TAS &
5 Tools will be stored in a securely locked container at all times SA Site Manager /
when not in use, and will not be removed from container AS 1873 –
Subcontractor / HSO
unless for use, repair or maintenance or left unattended Power
Activated
unless precautions are taken to ensure that it will not come Hand Held
into the possession of an unauthorised person. Fastening
5 tool
Logbooks will be available describing maintenance, repairs Site Manager /
VIC OHS Reg
and inspections undertaken. 2007 Part
Subcontractor / HSO
5 Every explosive powered hand held fastening tool will be: 3.6
Site Manager /
a) completely overhauled by the manufacturer or their Subcontractor / HSO
authorised agent at least once in each 12 month period;
b) cleaned at least once daily when in use; and
c) Inspected by a competent persons before each use.
5 Operators will have the appropriate licences as required by the HSO at Induction
relevant state legislation and copies will be provided to
Hutchinson Builders.
D 3 M9 3 Fire Emergency Exits/evacuations ways: WHS Reg D2 HSO /Site Manager
Fire Safe evacuation
☒ Protection on path
to be assessed to be clear of operational activities 2011 chapter
7 S/Div. 3 L5
that could have a major impact on safe movement of
Site VIC OHS Act
Fire control workers 2004 Part
equipment be a minimum of 1200mm wide 3.5
be the quickest route to identified exit internal stairs AS 3745 –
No knowledge of 2010
and scaffold stairs
safe procedures Planning for
be uncluttered and kept clear for the entire route to Emergencies
Explosion the exit stairs and down to the building exit AS 2444 –
be uncluttered from the building exit to the assembly 1995
areas Portable Fire
Extinguishers
have adequate lighting to ensure safe visual travel –
refer Electricity Supply
to be maintained on a daily basis and assessed on
Weekly Inspection Checklist
3 Site manager/
Fire Emergency Exit/Access Signage
foreman/ HSO
WHS Management Plan – Appendix 1 – Project Risk Assessment
Page 34
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
WHSMP.pdfRelated documentApplication case desk ↗
About this file
- File size
- 16.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.