                                                              requiring a greater luminance to perform their specific
                                                              activities in a safe manner.
                                                          5   Relocatable lighting will not be placed in a position where it                               Subcontractor / HSO
                                                               presents a trip hazard.
                                                          4   Wire guards or diffusers will be required to be provided to all                              Subcontractor / HSO
                                                              lighting to prevent damage.


                                          C   3    H13    5   All loading bays installed to have an approved SWMS in place           WH&S Reg       D3    Site manager /
    Loading Bays    Loading Bay
☒                    collapse                                 for the safe installation, moving and removing to and from the
                                                                                                                                      2011
                                                                                                                                      Chapter 5, 6   M9
                                                                                                                                                           foreman
                                                              building structure and to be used in conjunction with the crane                              Subcontractor
                                                                                                                                     VIC OHS Reg
                    Structural failure                       SWMS when manoeuvring the loading bay.                                  2007 Part            Rigger
                                                                                                                                      3.5
                    Falling Objects                      5                                                                     • AS/NZS
                                                                                                                                                           Site Manager /
                                                              Scaffold loading bays are to be design into the scaffold design   1680.1:2006                foreman
                                                              drawings for the project and be verified by an engineer            • AS/NZS                  Scaffold designer /
                                                                                                                                1680.2:2008
                                                                                                                                 • AS/NZS                  engineer
                                                          5   The following evidence must be provided before the Loading        3012:2010                  Manufacturer /
                                                                                                                                Electrical
                                                              Bays are to be used;                                                                         engineer / Site
                                                                                                                                installations -
                                                               Manufacturer details on the safe installation procedure         Construction and           manager / foreman
                                                                  and safe working procedure of the loading bay                 demolition sites           Subcontractor /
                                                               Engineer design details of the loading bay to be used –                                    Rigger
                                                                  relating to the various reactions and loading capacity and
                                                                  propped supports required
                                                               Project structural engineer’s approval as to where the
                                                                  loading bays are to be positioned in the structure and to
                                                                  the possible affect the operation of the loading bays may
                                                                  have on the structure
                                                          5   Only persons with the appropriate licences who are familiar                                  HSO at Induction /
                                                              with and competent in the installation of the type and size of                               Subcontractor
                                                              the loading bay to be installed will undertake tasks associated
                                                              with installation / removal / etc. of loading bays.


                                          C   4    E18    2   Tower crane will be provided for use by workers and                   WHS Reg         C3    Hutchinson Builder
    Manual          Manually handling
☒   Handling         excessive loads
                                                              subcontractors.                                                        2011 Part
                                                                                                                                     4.1             H13
                                                          2   Hoist will be erected on site for use by workers and                                         Hutchinson Builder
                                                                                                                                    VIC OHS Reg
                    Adopting poor                            subcontractors.                                                        2007 Part
                     postures when                        5   Material storage areas will be specified on site.                      3.1                   Hutchinson Builder
                     undertaking manual                                                                                             Hazardous
                                                          5   Mechanical equipment will be maintained in a safe condition            manual tasks          Hutchinson Builders/
                     handling tasks
                                                              and records kept.                                                                            Subcontractor


                                                  WHS Management Plan – Appendix 1 – Project Risk Assessment
                                                                                                                                                                            Page 47

Used in these records

About this file

File size
16.2 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

WHSMP.pdf · 16.2 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.