b) may only have small gaps that are absolutely necessary to
minimize wind resistance; and
c) Extend to the gantry’s overhead platform (if it is part of a
gantry).
5 A traffic management plan will be developed and include risk Site Manager
assessments, traffic controllers details and specific road
barricading and signage will be prepared and implemented
prior to work commencing on a road or footpath.
4 Vertical containment sheeting and perimeter containment
screening will be used and installed not more than 1m below
the height at which an object could fall from a surface or storey
to an area below. The screens will be capable of preventing an
object that may reasonably be expected to hit it from falling
from the level on which work is being done.
C 3 H13 1 Starter bar caps which are damaged or have deteriorated to a WH&S Act D3 Site Manager /
☒ Reinforcing
Bars (Starter
Contact with sharp
objects
condition where they no longer act as a visual warning / 2011 Part 2
M9
Foreman /
protect against impalement (as appropriate) will not be used WH&S Reg Subcontractor
bars) Trips and falls 2011 Part 6
onsite.
Protrusion hazard VIC OHS Act
2 Preference will be given to the use of starter bar caps that 2004 Part 3
offer some protection against impalement rather than being a
visual warning only.
2 Where possible, cranked starter bars will be purchased.
4 Starter bar caps will be used on site and installed in accordance
with the manufacturer’s recommendations.
5 Starter bar caps will be inspected for damage, deterioration
and correct installation.
C 5 E22 5 All tasks involving the erection, altering or dismantling of WH&S Reg D4 Subcontractor
☒ Scaffolding Collapse of
scaffolding
scaffold to have an approved SWMS in place and are to be in 2011 Part 6
S/Div. 4 H14
accordance with AS/NZS 1576. The SWMS will take into
QLD
Persons falling account at least the following hazards / issues (as applicable): Scaffolding
- collapse of scaffolding COP 2009
Objects falling - persons falling VIC OHS Reg
Part 3.5, 3.6,
Contact with - objects falling
5.1
overhead power - contact with overhead power lines
AS/NZ
lines - vehicle contact with scaffold 4576:1995
5 Scaffold plan will be on site for all scaffolding prior to erection AS /’NZ 1576 HSO / Foreman
Vehicle contact starting. Scaffold Plan will include information as required by .1 2010
with scaffold the Scaffold COP including, bracing, edge protection, Vic
supports, ties, access and egress etc. Compliance
WHS Management Plan – Appendix 1 – Project Risk Assessment
Page 61
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
WHSMP.pdfRelated documentApplication case desk ↗
About this file
- File size
- 16.2 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.