Specific Outcomes Probable solutions Proposal
S165.3 Buildings have a maximum wall Complies
length of 15m and each external wall Walls of buildings do not exceed 15m
plane incorporates at least one design without articulation (i.e. windows,
element to add visual interest and shading devices, wall insets, change in
amenity (such as windows, pergolas, building material and colour).
sun shading devices, balconies or a
change of building material).
Residential entry and pedestrian
access
O166 The residential component of the No solution provided Complies
development provides for— The development includes separate
a) separate identifiable residential identifiable residential entries to each
entries; unit. Clearly defined and safe pedestrian
b) clearly defined and safe pedestrian access is provided to each dwelling unit.
accesses to dwelling units and Appropriate lighting of pathways will be
accommodation units that are provided.
appropriately lit, visible to others and
directly accessible to units from areas Private and public spaces will be clearly
likely to be used at night; and delineated through the use of fencing
c) clear identification of what is private and landscaping treatments as well as
versus public space by using features building walls and changes in surface
such as low walls, changes in surface texture.
texture or other landscape treatment.
11.46 Minor Recreation/Minor Mixed Use/Open Space Precinct
Not applicable
Comment: The proposed development is able to comply with all the Probable Solutions for the Shire
Business Centre Zone with the exception of the Probable Solution S165.2 for building form, whereby
an Alternative Solution has been provided to satisfy the Specific Outcome.
RESIDENTIAL USES CODE
Table 14-24 — For All Residential Uses
Specific Outcomes Probable solutions Proposal
14.46 Effects of use
Electricity supply infrastructure S1.1 No solution provided. Complies
O1 The development does not adversely The proposed development will be
impact on existing or future electricity adequately serviced by existing
supply infrastructure; electricity supply infrastructure.
AND
O2 All uses and works maintain an S2.1 Development for uses adjacent to Not Applicable
adequate safe distance from electrical or within 50m of an existing electricity
infrastructure including substations, substation incorporates noise
overhead powerlines, power poles and attenuation measures to mitigate noise
transformers. impacts;
AND
S2.2 Buildings and structures (including Complies
swimming pools, sheds, tennis courts or No buildings will be constructed under
outbuildings) are not constructed under overhead electricity lines or easements.
overhead electricity transmission lines,
or within electricity easements;
AND
S2.3 A minimum separation distance is Complies
maintained from the electricity Minimum separation distances are
transmission line to the closest boundary achieved.
of habitable buildings and child activity
areas, as follows—
a) 20m for transmission lines up to
132kV;
b) 30m for transmission lines between
133kV and 275kV; and
c) 40m for transmission lines greater
than 275kV.
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application part 2 Report/Plans - MCU11/0254Related documentApplication case desk ↗
About this file
- File size
- 41.8 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.