Original PDF page 338, section 1. The text section number identifies this passage in the reader.

                                                                                                                                                                                                           Residual
                                                                                                                                                                                                                         Responsible




                                         Rating
                                         Initial
                                                                                                                          Proposed Controls




                                                         HOC
                                          Risk




                                                                                                                                                                                                             Risk
     Activity           Risks
                                                                                             (1/Elimination 2/Substitution 3/Isolation 4/Engineering 5/Administration 6/PPE)                                               Person
dismantle of                                                   - Co-ordination of scaffold works will be erected / dismantled during quiet times of the day.
scaffold                                                       - The bombing of scaffold components is not allowable during erection or dismantle.
                                                               - Tethering of tools and components when it is not possible to exclude adjoining areas
                  Falling objects        HIGH            5     Mesh used from perimeter screening will comply with the requirements of the relevant legislation / COP / Australian Standard.                          Site Management
                                                                                                                                                                                                                      Scaffold Contract
                                                                                                                                                                                                                           Partner
                  Scaffold collapse      HIGH            5     After erection / modification of any scaffold (excluding mobile scaffolds under 4m high), the Contract Partner erecting / modifying                    Site Management
                                                               the scaffold will provide a handover certificate.                                                                                                      Scaffold Contract
                                                                                                                                                                                                                           Partner
                  Unauthorised           HIGH            4     If a scaffold is incomplete or unsafe, and left unattended, the scaffold shall be excluded with the use of ‘Scaffold Incomplete’ signs                 Site Management
                  access or use                                and stop ends will be used to prevent unauthorised access onto the scaffold.                                                                           Scaffold Contract
                                                                                                                                                                                                                           Partner
                  Falling objects        HIGH            5     Gaps between the structure and scaffold shall not exceed 225mm horizontally, or 300mm vertically.                                                      Site Management
                                                                                                                                                                                                                      Scaffold Contract
                                                                                                                                                                                                                           Partner
Inspecting        Incomplete             HIGH            5     All Handover Certificates will notate the design drawing and the relevant Australian Standard to which they have been                                  Site Management
scaffold          handover                                     constructed.                                                                                                                                           Scaffold Contract
                  documentation                                                                                                                                                                                            Partner
                                                               A Handover Certificate will be received for all scaffold structures and loaded to Procore in conjunction with a marked Scaffold
                                                               Plan indicating the area being handover.
                                                               Where a Contract Partner has their own handover certificate this can be retained with the Woollam form and marked map.
                                                               Handover documentation is to be received prior to first use of the scaffold

                  Scaffold collapse      HIGH            5     The frequency of inspections may vary depending on weather and site conditions, the type and size of the scaffold and the risks                        Site Manager and
                                                               associated with scaffold collapse.                                                                                                                          Scaffold
                                                                                                                                                                                                                          Contractor
                                                               The scaffold and its supporting structure are inspected by a competent person:
                                                               (a) before the scaffold is used (Handover Certificate)
                                                               (b) before use of the scaffold is resumed after an incident occurs that may reasonably be expected to affect the stability of the
                                                               scaffold (Handover Certificate)
                                                               (c) before use of the scaffold is resumed after repairs (Handover Certificate)
                                                               (d) at least every 30 days Scaffold Inspection as found on Procore

Protection of     Mobile plant and       HIGH            4     Barricade exclusion zone will be erected to prevent vehicle contact with erected scaffolding in areas where there is vehicle traffic                   Site Management
scaffold during   traffic                                      closer than 1.5 meters from the face of the scaffold.
construction
works

References        AS/NZS 1576 Scaffolding
                  AS/NZ 1576 .1:2019 – Scaffolding – General requirements
                  Scaffolding COP 2021

                                                                                                                                                         Project Hazard/Risk Assessment / Page 96 of 160

Used in these records

About this file

File size
58.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

STP24-0253 Application for Operational Works Fire Trail - 80 Cooyar Street Noosa Heads.pdf · 58.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.