Original PDF page 339, section 1. The text section number identifies this passage in the reader.

                                                                                                                                                                                                                  Residual
                                                                                                                                                                                                                               Responsible




                                            Rating
                                            Initial
                                                                                                                                 Proposed Controls




                                                             HOC
                                             Risk




                                                                                                                                                                                                                    Risk
     Activity             Risks
                                                                                                    (1/Elimination 2/Substitution 3/Isolation 4/Engineering 5/Administration 6/PPE)                                              Person

Review and          Safety Interaction, Task Observation, Monthly Audit, Scaffold Inspection as per Procore Inspection Matrix.
Mentoring


     14.3           Tower Crane
Planning for the    Structural,         EXTREME              5                                                                                                                                                               Site Management
                                                                    Erection of Tower Crane Checklist on Procore shall be completed, and all relevant associated documents retained on site. Crane
installation of a   mechanical or                                   commissioning documentation to be retained on site along with all Crane safe inspections (initial and annual thereafter).
tower crane         attachment
                    failure

                    Crane collapse      EXTREME              5                                                                                                                                                                Site Manager
                                                                    The following evidence maintained on site:                                                                                                                 HSE Advisor
                                                                    -   Tower crane design registration.                                                                                                                     Contract Partner
                                                                    -   Tower crane registration.
                                                                    -   Certification of the base design by an engineer and the inspection requirements prior to pouring.
                                                                    -   10-year inspection certification
                                                                    -   The area around the crane is suitably barricaded off during erection.
                                                                    -   Full details of the procedures for operation of the tower crane.
                                                                    -   Load charts, in English, fixed in the operator’s cabin in a visible location (with stability information for mobile cranes).
                                                                    -   Certification that the following items meet the required safety standards:
                                                                          •    Tower bolts, tower to building ties, bracing, and bolting (NDT Testing)
                                                                          •    Access ladders, platforms, and guardrails
                                                                          •    Cleanliness of towers and crane generally
                                                                          •    Condition of ropes and sheaves
                                                                          •    Checking limits and safety devices
                                                                          •    Correct load radius indicator, Hook height indicator, Load weight indicator, motion limiting devices, rated capacity
                                                                               limiters.
                                                                          •    Wind speed indicator, audible warning devices.
                                                                          •    Letter of acceptance for the crane installation and tower to building ties where applicable
                                                                          •    Completion of log sheets
                                                                          •    Operation of load limiting device (AML – automatic load limiter)

                    Falling objects     EXTREME                     Where there is a risk of contact with power lines:                                                                                                            Project
                                                             3                                                                                                                                                                  Management
                                                                    -     The power lines will be de-energised and written confirmation of isolation provided by electrical entity; or                                       Site Management
                                                             5      -     Exclusion zones will be maintained and adhered to



                                                                                                                                                                Project Hazard/Risk Assessment / Page 97 of 160

Used in these records

About this file

File size
58.9 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

STP24-0253 Application for Operational Works Fire Trail - 80 Cooyar Street Noosa Heads.pdf · 58.9 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.