Council archive · source document
Decision Letter - Change to an Existing Approval - 010.2007.00001294.002 [As Published] · 142007.1294.02
2007/1294
7. Excavation of the site and the construction of the proposed works shall not have any adverse
affects on the stability of adjoining buildings and/or structures and/or services and/or lands. In
this regard a Registered Professional Engineer Queensland shall supervise the excavation of
the site and the construction of the new works to determine whether any additional measures
are required to protect the stability of adjoining buildings and/or structures and/or services
and/or lands.
8. The use of vibratory equipment of any kind is not permitted to be used (including vibrating rollers
and the use of vibrating installation techniques for sheet piling and other construction vibrations
caused by excavating, earthmoving or demolition machinery or other similar construction
techniques) unless approved and supervised by a Certified Geotechnical Engineer. Under such
circumstances the operator of such equipment shall at all times comply with the directions of the
Geotechnical engineer and the reasonable and lawful directions of Council officers.
9. All parts of the works (including excavation, retaining structures, tie backs etc) are to be wholly
contained within the subject site. Any subground structures (support anchors, tie backs etc) to
be utilised into adjoining properties, shall only be used if written permission has been granted by
the adjoining property owners.
10. Certification of the completed works must be provided to Council by the supervising engineer.
The certification shall state that the completed works conform with all aspects of the design and
that the completed works will not have any adverse affects on the stability of adjoining buildings
and/or structures and/or services and/or lands.
11. Suitable sediment control devices ("in pit” pollution control devices) shall be temporarily installed
into the first existing external downstream stormwater structure.
These devices are to be checked and cleaned on a regular basis and specifically after each rain
event.
These devices are to remain in place during the civil works and construction phases of the
development.
The location and type of device to be installed shall be established at the “pre start” meeting
with Council’s Construction Technical Officer and shall be installed prior to the commencement
of any works.
12. Council’s Construction Technical Officer – Michael Conroy (ph 0410 512 505), shall be given
seven (7) days’ notice of intention to commence works to arrange a “pre start” meeting prior to
the commencement of works.
13. The principal contractor must have all the appropriate insurance and public liability
documentation to carry out the works. The principal contractor is also responsible to ensure that
any sub contractors also have the appropriate insurance and public liability documentation.
14. Prior to the “pre start” meeting, the principal contractor must be provided with a copy of
Council’s signed approved drawings and conditions by the applicant.
15. The Consulting Engineers for the project shall be currently Registered Professional Engineers
of Queensland (RPEQ). The consulting engineers are responsible for arranging all inspections,
with Council’s Construction Technical Officer or nominated staff. Council’s Construction
Technical Officer shall provide an inspection form for signing off by the Engineer at appropriate
stages of construction, during on-site meetings. Construction Technical Officer will also sign the
form at each stage when conditions required have been satisfied. The works will be accepted
“On Maintenance” after this form, signed by the inspector for each stage is complete, together
with a letter from the Engineer requesting that the works go “On Maintenance”.
16. Prior to works commencing, Council is to be advised of the Engineer (RPEQ) supervising the
project. (This person will be the contact for the project).
17. Council standards shall apply to these works unless otherwise modified herein.
Page 3 of 9
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Decision Letter - Change to an Existing Approval - 010.2007.00001294.002 [As Published]Related documentApplication case desk ↗
About this file
- File size
- 63 KB (small file)
- File type
No other editions are linked here.