FOOTING OFF SEi
AS DETAILED

—|
uL
my —_ — — 28b_

SHADING INDICATES
100 THICK SLAB,
SL82 MESH,

40 TOP COVER

     
  

SS
aT POS

IE

Yr
ZA) SF1

— 400d MASS CONC.
fa. WIDENING TO SUIT

  

DOWEL BARS 10
POOL SHELL @
200 CTRS.

     

POOL AS DETAILED

400d MASS CONC.
3-117 TRENCH WIDENING TO SUIT
MESH 2000Lg TO

ALL INTERNAL

CORNERS

50d SHOWER
RECESS AS
DETAILED

     

SFI

 

 

REFER TO ARCHITECTURAL SPECIFICATIONS

SF1 FOR ALL SET OUT DIMENSIONS, FINISHINGS,
FLASHINGS, WATERPROOFINGS, ETC.

FOOTING & SLAB ON GROUND LAYOUT

1:100 at A3

BRICK VENEER WALL AS SPECIFIED

R10 TIE BARS @ 600 CTRS
200 COG TO FOOTING
400 LAP WITH SLAB REINF.

SL82 MESH,

    
  
 
 

BRICK VENEER WALL AS SPEC.

  
   
  

  
  

    
 
 
  

      
   

 

R10 TIE BARS @ 600 CTRS 25 TOP COVER s
200 COG TO FOOTING
400 LAP WITH SLAB REINF. npn
SL82 MESH, Ss
25 TOP COVER ~
: 2-N12 TIE BARS. 600 LAP,
R 200 COG TO ADJACENT FOOTING
S SLAB WITH VISQUEEN VAPOUR
+ BARRIER OVER (TYPICAL) 350 FOOTING SF1 AS DETAILED
3-L11 TRENCH MESH
50 COVER
350 SFI SBI
STRIP FOOTING DETAIL (SF1 SF1 /SB1 INTERSECTION DETAIL
aa NE ON NS RN
1:20 at A3 1:20 at A3

 

NOTES
1. This is the property of the engineer, and may not be used, copied,
of reproduced wholly, or in part without the express permission of

 

the engineer. infringement in any way may result in legal action.
2. Figured dimensions take precedence over scaled.
3. Verify atl dimensions on site.

emphrE

ENGINEERING wa

 

 

 

  

 

 

100 THICK SLAB. SL82 MESH
25mm TOP COVER (U.N.O.)

FOOTING SCHEDULE

350w x 400d R.C. STRIP FOOTING
350w x 400d R.C. SLAB BEAM

750w x 1500ig x 450d R.C. PAD
FOOTING

500w x 150d THICKENING

300w x 200d M.C. EDGE THICKENING
KEYED CONTROL JOINT AS DETAILED

 

 

      

GENERAL NOTES

1. ALL BEAMS TO HAVE Ni2 CORNER BARS
(500 x 500) TO MATCH REINF. AS
SPECIFIED. PROVIDE 2-N12 SPLICE BARS
(600 MIN. LAP) AT ALL BEAM JUNCTIONS

2. BASES OF ALL EXCAVATIONS TO BE

FINISHED SOUND AND FREE OF ANY

LOOSE MATERIAL PRIOR TO PLACEMENT

OF CONCRETE

      
        
   
   
      
    
 

ALL FOOTINGS TO FOUND INTO NATURAL
SURFACE BY MEANS OF DIRECT BEARING
ALTERNATIVELY PROVIDE 350% M.C.

BORED PIERS @ 2m CTRS TO FOUND 300
INTO NATURAL SURFACE

 
    
     
  
 

  

- TERMITE PROTECTION TO BE PROVIDED IN
ACCORDANCE WITH THE BUILDING CODE OF
AUSTRALIA AND OTHER RELEVANT CODES

 
   
 
 

  

. IF LARGE TREES ARE REMOVED DURING
SITE PREPARATION. THE VOIDS ARE TO
BE EXCAVATED, BACKFILLED &

COMPACTED WITH SUITABLE MATERIAL

SIMILIAR TO THE EXCAVATED MATERIAL

 
   
     
      

FILL COMPACTION NOTE

ALL IMPORTED MATERIAL TO BE APPROVED
GRANULAR FILL (100 MAX PARTICLE SIZE;
MIN SOAKED CBR=15) PLACED IN LAYERS
NOT EXCEEDING 200 AND COMPACTED TO
ACHEIVE NOT LESS THAN 98% MAX.
RELATIVE DRY DENSITY (STANDARD), OR

 
       
   
     

WITH AS 1289 WHERE TOTAL DEPTH OF
FILL EXCEEDS 400

CONCRETE GRADES

FOOTINGS -
SLABS -

N20 CONCRETE
N20 CONCRETE

 

 
   
  

SL82 MESH,

   

 

   

 

TIMBER STUD
FRAMING AS SPEC.

100

25 TOP COVER

2-N12 SPLICE BARS
MIN. 400 LAP

    
 
 
 

BEAM REINF
AS DETAILED

900

FOOTING OFFSET DETAIL

1:20 @ AZ

PROPRIETARY PRESSED
METAL KEY. 150 MIN
BEARING

 
   

200 COG TO FOOTING
400 LAP WITH SLAB REINF.

    
  
  
 
  

   

SS SE
ne oS ne

COMPACTED SANDBED UNDER
SLAB WITH VISQUEEN VAPOUR
BARRIER OVER

 

100

   

3-L11 TRENCH MESH
50 COVER

RIP FOOTING DETAIL + KEYED

CONTROL JOINT (SF1+KCJ)

1:20 at A3

SL82 MESH

100

    

SAND BED, ETC
AS BEFORE

EDGE THICKENING DETAIL (ET1)

1:20 at A3

 
   
  

TIMBER STUD
FRAMING AS SPEC.

SL82 MESH, sg,
25 TOP COVER

  

AS BEFORE
500

SLAB THICKENING DETAIL (TH1)

1:20 at A3

Approved:

   

 

 

 

 

>
+ SANDBED, ETC.
AS BEFORE
3-L11 TRENCH MESH
j<-J30_.4 50 COVER
SLAB BEAM DETAIL (SB1)
4:20 at A3
CONSULTING ENGINEERS Client: LEACH DEVELOPMENT GROUP
Dimer, earemeoneT Project: PROPOSED RESIDENCE

7

FAX O16

‘TROY MOBILE: 0413 108 149
EMAL:

ABN 21112761510

  

ACN 112761510

 

  
  
 

LOT 40 ASPERA PLACE,
NOOSA RETREAT

 

 

 
 

TB
TROY PAULSEN / RPEQ: 6990

 
 

 
 

    

R10 TIE BARS @ 600 ALT. CTRS.

Tt FOOTING AND SLAB ON GROUND
LAYOUT AND DETAILS

 
   
   
    

FOOTING BEAM REINF.
AS DETAILED

1-N12 CORNER
BAR. 500 LEGS

  
   
 

 

2-N12 SPLICE BARS 600
MIN. LAP, 200 COG

FOOTING BEAM REINF.
AS DETAILED

 

ee es |
fj |

 

 

     
 

JUNCTION CORNER
TYPICAL FOOTING JUNCTION DETAILS
£20 at A3

Yay BRICK PIER AS SPEC.

7 a BY ARCH

1-N16. CENTRAL

g L N16 STARTER BAR

| LAP 400 WITH COLUMN REINF.

Vi y COG 200 TO FOOTING

Y Y SL 82 MESH,

g O 40 TOP COVER

PSL. Z 4 YATRA
; nr R.C. SLAB, ETC. =
a AS DETAILED
@}—3-N12 U-BARS EACH WAY
50 COVER
750
x1500Ig

PAD FOOTING DETAIL (PF 2)

4:20 at A3

SL82 MESH Sq

25 TOP COVER =

300 MIN. LAP AT STEP SL82 MESH 2

 
 

25 TOP COVER

 
    

SANDBED, ETC.
AS BEFORE

100

SHOWER RECESS /
SLAB STEP DETAIL

1:20 at A3

   
 

     

Date JANUARY 2007| scate AS SHOWN
Job RefNo: | Drawing No: | Issue: |

SC-1188

 
 

 
 

 
 

  

 

Used in these records

About this file

File size
5.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

08_0197 - MCU - Detached House DJ Leach Pty Ltd [As Published].pdf · 5.7 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.