GD future-plus
ENVIRONMENTAL
4377-131119-1.0
4) Any depressions within the surface application area are to be filled with soils of same
category at horizon A.
5) Effluent warning signs must be clearly displayed in at least two places beside all
application areas.
The required setback distances as nominated in the Queensland Plumbing and Wastewater
Code 2011 have been summarised in Table 5 of this report.
4.2 MEDLI ASSESSMENT
Based on the resent investigation under by Future-Plus Environmental, in accordance with the
relevant legislation and guidelines, it was deemed unnecessary to undertake a MEDLI
assessment for the site. Rather the detailed site assessment has been undertaken in
accordance with the QLD Plumbing and Wastewater Code and AS:NZS1547:2000.
4.3 SETBACK DISTANCES
The setback distances from the effluent disposal area shall comply with the Queensland
Plumbing and Wastewater Code which is summarised below:
Table 5: Recommended Setback Distances for Secondary and Advanced Secondary Effluent
acre L Tg) Recommended Separation Distance
Footings or Buildings Boundaries of land application areas should be positioned at least
2.0m down slope or 4.0m up slope from the footing or where the site
is flat, 2.0m from any point of the building footing
Property boundaries, pedestrian paths and Boundaries of land application areas should be positioned at least
walkways, recreation areas 2.0m down slope, or 4.0m up slope or where the site is flat, 2.0m from
any point
Retaining wall footing Boundaries of land application areas should be positioned at least
2.0m down slope, or 4.0m up slope from the retaining wall footing or
where the site is flat, 2.0m from any point of the building footing
In ground swimming pool Boundaries of land application areas should be positioned at least
6.0m down slope, or 6.0m up slope from the pool or where the site is
flat, 6.0m from any point
In ground potable water tank 6m from the boundary of the land application area
Top bank of a permanent watercourse; Top 30m for secondary, 10m for advanced secondary
bank of intermittent watercourse; Top bank of a
lake; Top water level of a surface water source
used for agriculture, aquaculture or stock
February 2014 Site & Soil Evaluation Report 11
Wastewater Treatment and Effluent Disposal
314 Cooroy Mountain Road, Cooroy MountainSee the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalLog in to download the original file
Large file: the download may take up to a minute.
Searchable page text hides email addresses. Original files are unchanged and may show email addresses.