RECOMMENDATIONS ONLY – NOT THE FINAL DECISION OF COUNCIL
GENERAL COMMITTEE MEETING                                                    15 OCTOBER 2018


              ENVIRONMENTAL HEALTH
              Amenity
        13.   The development must be undertaken and operated in a manner that causes no
              detrimental effect upon the amenity of the neighbourhood by reason of the
              creation of excessive noise, lighting, air-borne hazards, atmospheric pollutants
              (including dust or odours) nuisance or any other emissions in accordance with
              the nuisance provisions of the Environmental Protection Act 1994.
              Noise Nuisance
        14.   Noise emission from mechanical equipment must comply with the following
              requirements:
                    Air-conditioning, refrigeration, fans including mechanical           exhaust
                    fans/ventilation, plant rooms and refuse compactors:
                        7am to 10pm: Maximum background + 5dB(A)
                        10pm to 7am: Maximum background + 3dB(A)
        15.   Submission of written certification from a suitably qualified person confirming that
              the noise levels from all mechanical equipment comply with the noise
              requirements of this Decision Notice when measured at either the residential
              boundary or outside the most exposed part of an affected building, whichever is
              the closest to the equipment.
              The assessment and certification is required immediately after installation of the
              equipment and prior to any occupation of the building, and in a format approved
              by Council. All equipment should be operating at the same time to test the overall
              noise level created.
              Kitchen Exhaust
        16.   Kitchen exhaust points for the development must be located and operated in
              accordance with Australian Standard AS1668.2-2002 “The use of ventilation and
              air-conditioning in buildings” (specifically Section 5.10 – Air Discharges).
        17.   The development must be constructed with reticulated ducting inside the building
              to transfer kitchen exhaust fumes to a discharge point on the roof.
        18.   Submission of written certification must be provided from a suitably qualified
              person confirming that the kitchen exhaust is constructed, installed and is
              operating in accordance with Australian Standard AS1668.2-2002.
              The assessment and certification is required immediately after installation of the
              equipment and prior to any occupation of the building, and in a format approved
              by Council.
              Service Vehicles
        19.   Deliveries to the site must be between 7.00am and 6.00pm Monday to Saturday
              and not permitted on Sunday or public holidays.




                                                                                    Page 5 of 26
Log in to download the original file

2018-10-15 General Committee Meeting Notes(PDF, 786KB).pdf · 805 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.