column 1 column 2
Including amendments to 3 July 2017
Specific Outcomes Acceptable solutions (if self-
The Noosa Plan
assessableaccepted development subject to
requirements)
Probable solutions (if code assessablecode
assessment)
iv. adversely affecting the privacy or building;
visual amenity of surrounding
properties
AND
O3 Finished surface levels ensure land is free S3.1 No solution provided
draining.
O4 Filling or excavation does not adversely S4.1 Fill material placed over services does not
affect sewer, stormwater or water utility impose any additional surcharge loading on the
infrastructure. service.
Editor’s note S4.2 Where excavation is carried out-
Council encourages building methods that avoid the c) a minimum cover of 600mm is maintained
use of fill, such as suspended floor construction and around all utility infrastructure (to top,
stepping down slopes rather than cutting and filling. sides and base of services); or
d) a retaining wall is provided to support the
soil surrounding the service;
Advisory note AND
Council encourages building methods that S4.3 Compaction with a vibrating roller is not
avoid the use of fill, such as suspended floor carried out within 600mm of any utility
construction and stepping down slopes rather infrastructure.
than cutting and filling.
S5.1 Buildings or other structures within the
Lake Macdonald catchment (indicated on Figure
14-15) are located above the 98.5m AHD level.
O5 Development does not adversely impact
on the Lake Macdonald water supply.
Electricity supply infrastructure
O6 Uses and works maintain an adequate S6.1 Buildings and structures (including
safe distance from electrical infrastructure swimming pools, sheds, tennis courts or
including substations, overhead powerlines, outbuildings) are not constructed under
power poles and transformers. overhead electricity transmission lines, or within
electricity easements.
Steep slopes and Landslide hazard areas
O7 Detached houses and associated uses S7.1 If on premises identified as a Landslide
are sited or constructed to maintain the safety of Hazard Area on Overlay Maps OM1.3–9.3 or on
people and property from the risk of landslide. steep slopes, the use does not—
a) involve the removal of vegetation other
than grass from use areas;
b) involve excavating or filling of more than
3
50m of material (other than placement of
topsoil not exceeding 100mm in depth
relative to natural ground level;
c) involve cut or fill with a vertical depth of
more than 2m relative to natural ground
level;
d) redirect or impede water flows in an
existing watercourse or stormwater drain;
or
102
Building Works Code
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
2017-06-06 - P&E Agenda Attachment 1 to Item 6 Draft Alignment Amendments Part 1 (Pages 1-907)(PDF, 18MB)Related documentPublic source context ↗Public source context ↗Public source context ↗
2017-06-06-p-e-agenda-attachment-1-to-item-6-draft-alignment-amendments-part-1-pages-1-907-pdfRelated documentPublic source context ↗
About this file
- File size
- 18.9 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.