      To ensure Council’s sewer main is accessible for maintenance purposes and is protected from
      risk of damage no structures requiring a building permit (eg. buildings, swimming pools,
      retaining walls exceeding 1m in height, raised terraces, etc) shall be constructed within this
      ‘zone of influence’ or within 1.5m of the centreline of the sewer main, whichever is the greater.
      In this regard the basement may need to be redesigned. As such the applicant shall amend
      Operational Works plans including Building plans to ensure compliance.
39.   All Building Applications will need a site plan prepared & certified by a licensed surveyor
      clearly illustrating the exact location of all sewer mains within the site or adjacent to the site
      and the ‘zone of influence’ of these mains.
Town Water Supply
40.   Each dwelling unit shall be connected individually to Council’s existing town water supply and
      be constructed in accordance with Council’s standards and requirements at no cost to Council.
41.   Each individual water connection to the water reticulation system shall extend to the property
      boundary and be metered. All fees for the supply of water meters shall be paid to the Council.
42.   All water meters must be located outside the property boundary and in an easily assessable
      location to facilitate unhindered reading by Council and/or Council’s contracted water meter
      readers, and not behind fences or locked gates. In this regard approval of the water meter
      configuration and location must be obtained from Council’s Water & Sewerage Capital Works
      Manager prior to lodgement and approval of hydraulic drawings.
Service Easements (Sewer)
43.   A registered easement shall be created over the zone of influence of all sewers within the
      subject site and over those parts of the subject site that are impacted upon by sewers on any
      adjoining sites. The easements shall generally be parallel to and centred over the sewer main
      and be equivalent in width to twice the depth to invert level of the sewer at the deepest point
      within the allotment (measured from the finished surface) and be no less than 3.0m wide
      overall. In this regard a licensed surveyor shall accurately locate all sewer mains and
      determine the necessary width of the easement, which shall be shown on any plans submitted
      for Operational Works / Building Works approval. To this extent the surveyor shall certify that
      the sewer and the zone of influence is wholly contained within the easement to be created.
      In addition to this the Applicant’s Solicitor shall give Council’s Solicitor an appropriate
      undertaking in writing that the Title Deed and the easement documents will be lodged at the
      Land Titles Office and any additional Titles Office forms or requisitions requiring the consent of
      Council will be attended to promptly.
      A duly executed copy of the easement shall be submitted to Council for perusal prior to the
      use commencing.
      Any changes required by Council’s Solicitor must be corrected immediately.
44.   No building or other structure shall be constructed or encroach over an easement.
45.   Any building or structure within proximity of an easement or any other public utility’s
      underground must have its foundations designed so that no surcharge loads are imposed
      upon such underground infrastructure. Foundations must be taken down a minimum of 1.0m
      below a line of influence measured 1.0m in the direction of the foundation from the centreline
      of the closest underground service and along the natural angle of repose of the foundation soil
      type(s).
      Also, foundations for retaining walls and masonry fences across a sewer main shall be
      properly designed and constructed, in consultation with Council’s Sewer Section, to minimize
      impact on the sewer main and facilitate future maintenance and upgrading works.



                                                                                      Page 6 of 14

Used in these records

About this file

File size
82 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Decision Letter - Change to an Existing Approval - extension to relevant period [As Published].pdf · 82 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.