Skip to the record
Beware of cheap imitations.

Council archive · source document

SPA Decision Notice - 010.2010.00000515.001 [As Published] · 152010.515

of 8

Text shows just the words. Original shows the document exactly as it was published.

                                                                                         2010/515



23.   Any filling or retaining works must not direct overland flows onto any adjoining properties.

Erosion and Sediment Control
24.   Any person acting on this permit shall prevent erosion and sediment export from leaving the
      site. Site control measures such as silt fencing, controlled gravel access to the site and
      controlled disposal of waste, will be necessary.
      In this regard, plans detailing the methods of controlling erosion and sediment are required to
      be submitted to the Council for approval prior to obtaining a Development Permit for
      Operational Works.
General Engineering Requirements
25.   A suitably qualified Registered Professional Engineer shall prepare engineering drawings and
      specifications for all engineering works that will become Council infrastructure, which shall be
      submitted in conjunction with an application for a Development Permit for Operational Works.
      In this regard a DXF/DWG file on GDA94 zone 56 grid of the proposed cadastre layout is to be
      submitted in conjunction with any application for Operational Works.
26.   Digital detailed designs including drawings, calculations, etc, shall be submitted with any
      application for a Development Permit for Operational Works in respect of roadworks and
      stormwater drainage works. The design shall be in accordance with Council’s Planning
      Scheme Policy PSP05 – Engineering Design Standards – Roads, Drainage and Earthworks.
      To avoid conflict with underground pipes or services, all existing and proposed services
      required by the development shall be shown on the plans.
27.   To facilitate production of As Constructed drawings it is suggested that all design drawings are
      submitted in the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the
      use of ADAC are available at www.adac.com.au).
28.   Any damage caused to any public utility during the course of construction shall be repaired to
      Council’s standards and at no cost to Council.
29.   Any alteration of any public utility or other facilities necessitated by the development of the
      land or associated construction works external to the site shall be at no cost to Council.
30.   As Constructed drawings and data shall be certified by a qualified experienced Civil Engineer
      for design intent, and a Licensed Surveyor shall certify the cadastre and the location, level and
      type of all services and structures. All of which shall be submitted to Council for checking and
      for Council’s records.
      The data must fully detail levels for all engineering works including but not limited to drainage
      structures, finished ground levels and pavement surface levels. The data shall be submitted in
      the Asset Design and As Constructed (ADAC) digital format. (Guidelines on the use of ADAC
      are available at www.adac.com.au).
      Approval of works shall not be granted until all As Constructed information has been supplied
      and accepted by Council.
UnityWater
Water & Sewerage
31.   Reticulated water must be provided to each lot in the development. This must include:
      31.1 Ensuring that existing internal water pipes are wholly contained within the lot they will
           serve; and
      31.2 An approved water meter for each lot in accordance with Sunshine Coast Water
           Standard Drawings SCW 350,355 and 360.
32.   Reticulated sewerage must be provided to each lot in the development and include existing
      sewer house drains are wholly contained within the Lot they will serve.

                                                                                      Page 4 of 8

Used in these records

About this file

File size
61 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

SPA Decision Notice - 010.2010.00000515.001 [As Published].pdf · 61 KB (small file)