18Sunseel?gr Crose
the certifier
pillars;
b) 4m from street lamps;
c) 2m from stormwater
catchment pits; and
d) 2m from underground
services and utilities;
AND
57.5 Plants are located to
enable tradespersons
to access, view and inspect
service meters, such.
as water and electricity meters;
AND
57.6 Root barriers are installed
around trees that
are located within 3m of any
infrastructures or that
have potentially invasive roots.
Entry Statements
08 Tree and plant massing are 58.1 No solution provided. There is no particular entry
the dominant features of entry 59.1 Entry statements are low
statement proposed for the
statements to residential or maintenance and located
development. A small are of
commercial estates and are entirely within privately owned
integrated with the landscape land. landscaping is proposed along
theme of the estate and the the front boundary and visitor
natural landscape character of car parking area.
the locality, rather than the entry
being dominated by built Relevant conditions of
elements such as masonary
walls, waterfalls and assembled
approval can be included in the
rock outcrops. (see Figure 14- development permit.
19).
Proposal complies
09 Entry statements are low
maintenance.
14.135 Specific Requirements for Multiple Housing and Visitor Accommod tion
Private Open Spac.e
010 Private open space is- 510.1 For Multiple housing Each unit is provided with a
a) provided to all dwelling units Types 2 and 4, each
private open space area
and accommodation units; dwelling unit provides for
greater than the prescribed
b) of adequate size and landscaped private open
dimensions to suits the needs of minimum requirements at
space comprising-
occupants; a) for units at ground level, a ground level.
c) clearly set apart for private minimum area of 25m2 exclusive
use and separate from of the clothes drying area, Sufficient area has been
communal areas; with minimum dimensions of 4m
provided for service areas
d) directly accessible from a and maximum gradient of 1 in
including clothes line.and bin
living area of the unit; 10(10%);or
e) located away from noise b) for units above ground level, areas, in additional to
generating uses; a minimum area of
12m2, with recreational private open
f) capable of receiving adequate minimum dimensions of 2.5m; space
32
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Development Application part 2 of 2 plans - MCU13/0080Related documentApplication case desk ↗