Council archive · source document
Part 8 of 37 Appendix 6 - Flood Study MCU12/0208
Very large file (93.6 MB): the whole original can take several minutes to open, especially on a phone. Text is quick to read.
Noosa on Weyba
Flood Study
~,.,CardnO.
Hollett Road Upgrade (Hollett Road West)
The minimum road level will need to be set at 7.35 mAHD. 10 year ARI flood immunity is proposed with
PMF trafficability.
The existing low flow pipe should be replaced with 3/1200 by 450 RCBCs (upstream IL 6.55 mAHD, =
downstream IL = 6.50 mAHD, length = 12m). Approximately 12 metres to the west 3/1200 by 450 RCBCs
(upstream IL 6.65 mAHD, downstream IL
= 6.60 mAHD, length
=
12m) should also be installed. No
=
excavation beyond the road reserve will be required.
For the previous development application for this section of the site a drainage channel located on the
northern side of the Hollett Road was proposed, to improve local drainage. This would require clearing of
vegetation. For this application this drainage channel has not been included, and larger culverts have
instead been utilised to provide sufficient flood immunity. This will minimise the amount of vegetation
clearance required.
Easement Crossing
This crossing is not required for access purposes for the site. However, it could potentially be utilised by
existing properties around Lake Entrance Boulevard and Aspera Place as an alternative flood access route,
as 70 properties in this area are inaccessible during a 2 year ARI event and above.
The minimum road level will be set at 4.30 mAHD. 10 year ARI flood immunity is proposed with 100 year
ARI trafficability.
The proposed culvert is a 1/1500 by 1500 RCBCs (upstream IL = 2.00 mAHD, downstream IL = 1.95 mAHD,
length =
15m).
Tidswell Road Crossing
An upgrade of Tidswell Road is proposed as a secondary access route for the development. It is proposed
that the existing track will be upgraded by Council, as a cost to the subject development, so that 5 year ARI
flood immunity is provided, as required for rural roads. The minimum road level will be raised from around
3.40 mAHD to 4.15 mAHD.
The proposed culverts include 3/1500 by 600 RCBCs (upstream IL = 3.30 mAHD, downstream IL = 3.15
mAHD, length =
15m) and 1/1500 by 600 RCBC (upstream IL = 3.35 mAHD, downstream IL = 3.10 mAHD,
length =
15m).
Southern Keyser Creek Crossing
This crossing of the creek will link Precincts F and G using the route of an existing rural dam wall. The
minimum road level was set at 3.15 mAHD. It is proposed that this crossing have 100 year ARI flood
immunity (with climate change). This crossing will not be trafficable during a PMF event, but alternative
access for Precinct F is provided along the fire trail located along the southern boundary of the site. This fire
trail will therefore need to be formalised so that it can perform this function.
The culverts will consist of 7/3000 by 1500 RCBCs (upstream IL = 0.90 mAHD, downstream IL = 0.85
mAHD, length 35m). Approximately 30 metres to the east a 2700 by 1200 RCBC (upstream IL
= = 1.35
mAHD, downstream IL 1.30 mAHD, length
=
12m)will be installed to drain local flows in this area.
=
The entry and exit losses were assumed to be 0.4 and 0.7 as wingwalls between 30 and 70 degrees will be
utilised, and scour resistant outlet pad will be installed (refer Section 7.16.2 of QUDM).
Northern Keyser Creek Crossing (Hollett Road East)
This crossing of the creek will provide access to Precincts A, B, C, D and E. The minimum road level is 4.00
mAHD. It is proposed that this crossing have 100 year ARI flood immunity (with climate change) and be
trafficable during a PMF event. The culverts will consist of 7/3300 by 1500 RCBCs (upstream IL = 0.85
mAHD, downstream IL = 0.80 mAHD, length = 35m).
The entry and exit losses were assumed to be 0.4 and 0.7 as wingwalls between 30 and 70 degrees will be
utilised, and scour resistant outlet pad will be installed (refer Section 7.16.2 of QUDM).
Northbrook Corporation Pty Ltd Version 1 23 October 2012
Flood Study v1.doc Commercial in Confidence Page 20
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Part 8 of 37 Appendix 6 - Flood Study MCU12/0208Related documentApplication case desk ↗
About this file
- File size
- 93.6 MB (very large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.