Original source · versioned page text
Attachment 13 - Code Assessment
Noosa Plan 2006 Planning Scheme Code Assessment
Division 16 - Specific Outcomes for the Cooroy & Lake Macdonald Locality
Specific Outcomes Probable Solutions Comment
i. causing ponding of water on the site or nearby land; AND
ii. increasing flooding, which adversely affects the safety S14.2 Where Council infrastructure is available— Complies. The proposed carparking areas have been
or use of any land upstream and downstream; and a) any drainage (including buildings and yards) flows designed to naturally drain to stormwater infrastructure.
iii. adversely affecting the flow of water in any overland to that infrastructure; and
flow path. b) the infrastructure has the capacity to accept any
additional loading;
AND
S14.3 Car parking and maneuvering areas are constructed Not applicable. The proposed development does not
at a level that permits the parking area to drain from the propose basement carparking.
site by gravity means, without the need for mechanical
pumping; or
S14.4 Basements for residential uses have flood immunity Not applicable. The proposed development does not
above the 1%AEP defined flood event where alternative propose basement carparking.
means to mechanical pumping are used to achieve such
immunity; or
S14.5 Basements for non-residential uses have flood
immunity above the 1%AEP defined flood event that may
be achieved by means of mechanical pumping where the
mechanical feature is installed with adequate holding
tanks and an alternative back up power source
Sloping sites
O15 On sloping sites, buildings and structures are S15.1 Buildings are of split level design that step down the Not applicable. The subject land does not reflect
designed to maximise the use of natural slope and slope or have a suspended floor construction; (See Figure characteristics of a sloping site. Buildings will not be split
minimise the need for cut and fill. 6.1 below) level design.
AND
S15.2 Cut or fill is less than 2m in depth; Complies. The extent of excavation and filling works
AND required to accommodate the proposed development has
S15.3 The distance between the ground and the lowest been minimised as far as practicable.
part of the floor of the building does not exceed 3m.
Not applicable. Buildings will be slab on ground
construction.
Page 5 of 26
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalSearchable page text hides email addresses. Original files are unchanged and may show email addresses.