                                                                                                      OPW17/0225

                              c.       Works programme identifying key components of the works and their
                                       respective durations.
                              d.       Identification of complaint management procedures including:
                                       i.    Contact details for the on-site manager.
                                       ii.   Dispute resolution procedures.
                      13.     Any changes to the details associated with the supervising RPEQ or Principal
                              Contractor during construction, must be notified to council in writing within five
                              business days of the change occurring.
                      14.     Any conflict between the development and an existing or proposed service must be
                              referred to the relevant service authority for determination prior to commencement
                              of works.
                      DURING CONSTRUCTION
                              General
                      15.     All works must be constructed and work procedure undertaken in accordance with:
                              a.       The approved plans and conditions detailed in this Decision Notice.
                              b.       The relevant conditions of the higher order Material Change of Use approval
                                       file 132003.221172.7 (23657 DA) to which this approval relates.
                              c.       All relevant Noosa Council Planning Scheme Policies, standard drawings,
                                       standard specifications and guidelines.
                              d.       The latest version of the Healthy Waterways document “Water Sensitive
                                       Urban Design Technical Design Guidelines for South East Queensland” for
                                       all water quality devices to be constructed on site.
                              Driveway
                      16.     Driveway crossover must be constructed generally in accordance with the
                              approved plans and be in compliance with IPWEA Standard Drawings RS-049 and
                              RS-050, and with a longitudinal profile that ensure standard vehicle entering or
                              leaving the site will not bottom down or scrape.
                      17.     Where there is adjoining a pedestrian path (existing or proposed), a crossfall must
                              be provided for the driveway to match the gradient of the path, for the full width of
                              the path.
                      18.     The following must be complied with during the construction of the required
                              crossover/driveway:
                              a.       The driveway surfacing must consist of either an approved hot mixed
                                       asphaltic concrete or plain/patterned concrete.
                              b.       The driveway must be constructed so as not to concentrate stormwater
                                       runoff or ponding onto other properties or onto road verge and pathway.
                              c.       Where applicable, underground service conduits for water supply, electricity
                                       and any other services must be provided as part of the access driveway
                                       works.
                              d.       Any stormwater kerb outlet in close proximity to the edge of the new
                                       driveways must be provided with an approved kerb adaptor.
                              e.       Have a minimum clearance of 500mm from any Unitywater/Telstra asset,
                                       unless a written approval is obtained from Unitywater/Telstra and submitted
                                       to Council.



                                                                                                             Page 4 of 13


Document Set ID: 20417363
Version: 3, Version Date: 05/09/2017                                                               Print Date: 5 September 2017, 4:08 PM

Used in these records

About this file

File size
1.4 MB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Att 1b - OpWorks Decision Notice.pdf · 1.4 MB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.