40. All internal roads shall be designed and constructed in accordance with Council’s
Planning Scheme Policy 5 – Engineering Design Standards – Roads, Drainage and
Earthworks. The roads shall be:
40.1 Generally in accordance with drawing number ‘Masterplan’ prepared by
Thomson Adsett dated 15 October 2020, Plan Ref: DA_106 Rev. 3,
40.2 A minimum width of 5.5 metres, and
40.3 Suitable for Council’s refuse collection vehicle to traverse through the site
Car Parking
41. Carparking shall be provided within the sites generally as shown on drawings
numbered DA_114 “Masterplan/Carpark Layout” Rev. 3 prepared by Thomson Adsett
Architects dated 15 October 2020 and DA_133 “Apartment Buildings – Basement”
prepared by Smith and Tracey Architects dated November 2018 and within the
“Independent Living Units” as shown the approved floor plans, except as modified
herein.
Storm Water Quality
81. Any proprietary stormwater quality improvement device included to achieve the
required stormwater quality Management Objectives specified in Section 4 of the
Girraween Stormwater Management Plan, must demonstrate only be granted an
Operational Works Approval on the following provisions:
a. A suitably qualified and experienced professional must provide independent
verification that the parameters within the node for the device in MUSIC modelling
have been tested and verified as per Stormwater Australia (2018) Stormwater
Quality Improvement Device Evaluation Protocol. Version 1.2 December 2018 to
achieve the predicted outcomes in the MUSIC model for the development. For
the purpose of this condition, the suitably qualified and experienced professional
must be able to demonstrate a minimum 10 years urban stormwater testing and
modelling experience and be verified in writing by Stormwater Australia as having
an appropriate reputation and track record within the stormwater industry to
provide such independent advice.
b. Where testing to achieve the certification of the proprietary stormwater quality
improvement device is from an area with rainfall intensities and patterns that are
statistically inconsistent with the region of the Noosa Shire that the device is to
be installed, and / or the size of the development the device has been tested on
is more than 2500m2 smaller than the development the device is proposed to
service, the following additional conditions apply:
i. The proprietary stormwater device treatment train must be tested and re-
verified in accordance with the Stormwater Australia (2018) Stormwater
Quality Improvement Device Evaluation Protocol. Version 1.2 December
2018. A suitably qualified and experienced professional, as verified by
Stormwater Australia must use the results from the onsite testing to re-run
the MUSIC node for the proprietary devices and confirm whether or not the
required pollutant reduction efficiencies of 80% reduction in Total
Suspended Solids, 60% reduction in Total Phosphorous and 45%
reduction in Total Nitrogen for the overall development are delivered.