Council archive · source document
Appendix E Business Activities Code · MCU20/0090
Appendix F Business Activities Code Development Permit for Material Change of Use for an Office Ancillary to a Landing (extension to an existing jetty building) at 256 Gympie Terrace Noosaville described as Lot 158 on SP1460413 Table 9.3.7.3 Assessment Criteria Performance outcomes Acceptable Outcomes Compliance O1 Business activities are compatible with the No acceptable outcome provided The office and storage extension is purpose of the zone in which they locate and compatible with and subordinate to the the site is suitable for the use having regard to existing recreational and marine uses accessibility, infrastructure and servicing. on the jetty. PO2 The business activity is located within an existing No acceptable outcome provided As detailed above the office and storage business centre or visitor centre shown in the extension is a use that is considered Noosa Shire Centres Hierarchy or in an industrial ancillary to the existing facilities on site. zone. The extension is considered compatible with the existing services and facilities on site. PO3 Business activities are of a type, scale and No acceptable outcome provided The office extension is compatible with intensity that is consistent with the zone, locality and subordinate to the existing and character of the area in which it is located and recreational and marine uses on the reinforces the Noosa Shire Centres Hierarchy. jetty. O4 Business activities contribute to the local economy No acceptable outcome provided The extension enables the safe and and vibrancy of the area in which it is located. efficient functioning of the existing activities on site PO5 AO5.1 Development is sufficiently separated from Buildings and structures are not constructed Not applicable - located under existing infrastructure including electricity infrastructure under overhead electricity transmission lines, building line. and substations to minimise the likelihood of or within easements. nuisance or complaint. AO5.2 Development adjacent to or within 50 metres of a substation, major electricity infrastructure or major utility incorporates noise attenuation measures such that noise levels do not exceed 5db(A) above background noise level internal to buildings measured in accordance with AS1055. AO5.3 Where adjoining substations, major electricity infrastructure or major utilities, buildings are orientated so that the majority of windows and doors face away from the infrastructure. Ground floor PO6 AO6 Ground floor spaces and ceiling heights are Ground floor spaces have a minimum ceiling Premises have been designed to be flexible to cater for a range of business activities. height of 3.5 metres to allow flexibility of use located within the existing building form (for example; adaptation for shop, restaurant and on the jetty. The design is suitable or office uses) for the intended uses of the site. Outdoor areas PO7 AO7 Proposal does not propose any new Outdoor areas, including balconies and rooftops, Outdoor areas and roof top areas used for outdoor areas used for business activities are located, designed business activities are located away from and operated to avoid causing nuisance to sensitive land uses and are generally oriented adjoining or nearby sensitive land uses. towards the street. Page 2
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
Appendix E Business Activities Code.pdfRelated documentApplication case desk ↗
About this file
- File size
- 205 KB (small file)
- File type
No other editions are linked here.