FIGURE 6: STORAGE VOLUME GRAPH FOR THE PROPOSED DETENTION TANK
Table 7 compares the pre-developed unmitigated flows against the mitigated post-development
flows.
TABLE 7: PRE-DEVELOPMENT FLOWS VS. POST-DEVELOPMENT MITIGATED FLOWS
Existing Case - Unmitigated Developed Case - Mitigated
Catchment ID / Catchment Total Discharge Catchment Total Discharge
Storm Event Description (m³/s) Description (m³/s)
1% AEP PreDevCat 0.062 PostDevCat 0.046
2% AEP PreDevCat 0.055 PostDevCat 0.041
5% AEP PreDevCat 0.047 PostDevCat 0.035
10% AEP PreDevCat 0.040 PostDevCat 0.031
20% AEP PreDevCat 0.033 PostDevCat 0.025
50% AEP PreDevCat 0.023 PostDevCat 0.017
63.2% AEP PreDevCat 0.020 PostDevCat 0.015
24083 – 51 Elanda Street, Sunshine Beach - SMP Page 13