                                                                                         2007/2398




Water Supply
77.   The site must be connected to Council's existing town water supply and be constructed in
      accordance with Council's standards and requirements at no cost to Council.
78.   Works be carried out in accordance with the approved findings of the water supply network
      analysis by Worley Parsons and dated 10 June 2008
79.   The existing 100mm diameter watermain within Pearson Road must be upgraded between the
      existing 150mm diameter main in Carruthers Court to the existing 150mm diameter main to the
      North in Pearsons Road
80.   The water connection to the water reticulation system shall extend to the property boundary and
      be metered. All fees for the supply of water meters shall be paid to the Council
81.   For Multiple Uses (including Building Format Plans, Group Title Plans, etc) the development shall
      be served by:
      81.1 Single Body Corporate water meter to measure the total water consumption (including fire
           hose reels, but excluding fire hydrants and fire sprinkler systems)
      81.2   Individual water meters to each tenement capable of being separately rated. These meters
             must be supplied and installed in accordance with Councils requirements
      81.3   All water meters must be located in an easily assessable location to facilitate
             unhindered reading by Council and/or Council’s contracted water meter readers, and
             not behind fences or locked gates
      81.4   A fire service (fully testable single detector check with metered bypass), where applicable,
             for flows to fire hydrants and fire sprinkler systems (excluding fire hose reels)
82.   Fire hydrants are to be provided throughout the development in accordance with Council
      Engineering Design Standards and in accordance with Queensland Fire Service Standards.
Service Easements
83.   A registered easement shall be created over the zone of influence of the proposed sewer
      mains within the subject site and on the adjoining property Lot 4 RP 215622. The easements
      shall generally be parallel to and centred over the sewer main and be equivalent in width to
      twice the depth to invert level of the sewer at the deepest point (measured from the finished
      surface) and be no less than 3.0m wide overall. In this regard a licensed surveyor shall
      accurately locate all sewer mains and determine the necessary width of the easement, which
      shall be shown on any plans submitted for Operational Works / Building Works approval. To
      this extent the surveyor shall certify that the sewer and the zone of influence is wholly
      contained within the easement to be created. The applicant must be pay all costs associated
      with the acquisition and the registration of easement/s.
84.   The Applicant’s Solicitor shall give Council’s Solicitor an appropriate undertaking in writing that
      the Title Deed and the easement documents will be lodged at the Land Titles Office and any
      additional Titles Office forms or requisitions requiring the consent of Council will be attended to
      promptly.
      A duly executed copy of the easement shall be submitted to Council for perusal prior to the
      use commencing.
Power Supply
85.   An underground electricity service shall be provided to the site if not already provided.
      In this regard, an approved ENERGEX Electrical Design Consultant shall work in conjunction
      with Council’s Manager - Works Support to prepare detailed designs of the electrical proposal.
      The detailed deigns shall then be submitted to ENERGEX for approval and a copy of their
      approval submitted to Council in conjunction with a “Certificate of Electricity Supply for
      Proposed Subdivisions” (prepared by an approved ENERGEX Electrical Design Consultant)
      prior to Council endorsing the Plan of Survey.
                                                                                          10 of 31

Used in these records

About this file

File size
645 KB (small file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_2398 - SUPERSEDED Negotiated Decision Notice & copy sent to Referral Agencies [As Published].pdf · 645 KB (small file)

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.