Skip to the record
Trusted by locals. Built for Noosa.

Original source · versioned page text

Appendix K - Hydraulic and Wet Fire Services Report

of 14

Page text shows just the words. Original shows the document exactly as it was published.

                                                             BRW Enterprises (Qld) Pty Ltd
“DA Report”, PF 80 Cooroy Care Farm Development for LCC.                           Page : 7
______________________________________________________________________________________

1.4 COLD WATER SERVICES

The potable and non-potable cold water services shall be sourced from a rainwater harvesting
methodology strategy, whereby all roofwater is captured and harvested in storage tanks, with
treatment applied commensurate with use. Low treatment will be provided for water to be used for
toilet flushing, whilst high treatment processes shall be applied for water that shall be consumed in
potable applications.

Furthermore, a bore shall be constructed on the site, and is proposed for supply of all non-potable
water services. However, further water testing of the bore water shall further confirm the
capacity/quality of such water to be used for other purposes – either with or without treatment.

The cold water system shall conform to the following Australian Standards :-

                AS 1167          Welding and Brazing – Filler Metals
                AS 1345          Identification of the Contents of Piping, Conduits and Ducts
                AS 1432          Copper Tubes for Plumbing, Gasfitting and Drainage Applications.
                AS 1530.4        Methods for Fire Tests on Building Materials, Components and
                                 Structures. Part 4 - Fire Resistance Tests of Elements of Building
                                 Construction
                AS 1628          Water Supply - Copper Alloy Gate, Globe and Non-Return Valves.
                AS 1718          Water Supply - Copper Alloy Screw Down Pattern Taps –
                                 Specified by Dimensions
                AS 2129          Flanges for Pipes, Valves and Fittings
                AS 2638          Sluice Valves for Waterworks Purposes
                AS 3500          National Plumbing and Drainage Code – Compendium
                AS 3500.1.2      Water Supply
                AS 3500.4.2      Hot Water Supply Systems
                AS 3688          Water Supply – Copper and Copper Alloy Body Compression and
                                 Capillary Fittings and Threaded-End Connectors.

The design shall encompass all piping, valves, unions, fittings, and sundry equipment to the
satisfaction of the Noosa Shire Council.

Water services pipework shall be as follows :-

           all 100mm (or larger) inground water service pipework shall be either copper or poly
            pipe suitably sized in accordance with the areas serviced;
           all inground water service pipework less than 100mm shall be copper. The size of such
            pipework shall be in accordance with the fixtures/areas being services;
           all water service pipework within buildings shall be copper. No pressurised services
            shall be located in slabs.




                                                                               Document : 14,967/da-rep/A
Log in to download the original file

Appendix K - Hydraulic and Wet Fire Services Report.pdf · 544 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.