GENERAL COMMITTEE MEETING AGENDA 15 OCTOBER 2018
Protection of Privacy
12. To ensure privacy is protected between adjoining properties all windows and glass
doors located on the upper level of the southern building face must either:
have a minimum window sill height or 1.5 metres above floor level
be fitted with translucent glazing
be fitted with a fixed external screen
ENVIRONMENTAL HEALTH
Amenity
13. The development must be undertaken and operated in a manner that causes no
detrimental effect upon the amenity of the neighbourhood by reason of the creation of
excessive noise, lighting, air-borne hazards, atmospheric pollutants (including dust or
odours) nuisance or any other emissions in accordance with the nuisance provisions
of the Environmental Protection Act 1994.
Noise Nuisance
14. Noise emission from mechanical equipment must comply with the following
requirements:
Air-conditioning, refrigeration, fans including mechanical exhaust
fans/ventilation, plant rooms and refuse compactors:
7am to 10pm: Maximum background + 5dB(A)
10pm to 7am: Maximum background + 3dB(A)
15. Submission of written certification from a suitably qualified person confirming that the
noise levels from all mechanical equipment comply with the noise requirements of
this Decision Notice when measured at either the residential boundary or outside the
most exposed part of an affected building, whichever is the closest to the equipment.
The assessment and certification is required immediately after installation of the
equipment and prior to any occupation of the building, and in a format approved by
Council. All equipment should be operating at the same time to test the overall noise
level created.
Kitchen Exhaust
16. Kitchen exhaust points for the development must be located and operated in
accordance with Australian Standard AS1668.2-2002 “The use of ventilation and air-
conditioning in buildings” (specifically Section 5.10 – Air Discharges).
17. The development must be constructed with reticulated ducting inside the building to
transfer kitchen exhaust fumes to a discharge point on the roof.
18. Submission of written certification must be provided from a suitably qualified person
confirming that the kitchen exhaust is constructed, installed and is operating in
accordance with Australian Standard AS1668.2-2002.
The assessment and certification is required immediately after installation of the
equipment and prior to any occupation of the building, and in a format approved by
Council.
Service Vehicles
19. Deliveries to the site must be between 7.00am and 6.00pm Monday to Saturday and
not permitted on Sunday or public holidays.
Page 5 of 55