MCU14/0056 Information Request

of 12

Page text shows just the words. Original shows the document exactly as it was published.

                                                                                MCU14/0056



       (k)    Provide predictions of cumulative commercial noise impacts for various
              operating scenarios to confirm compliance with the criteria the Ferrell Street
              receptors for the commercial uses on the development site.
       (l)    Provide an assessment of the noise impact of the changed traffic volumes on
              Ferrells Road to the existing sensitive receptors in this road.
       (m)    Provide further information regarding noise character adjustment for noise
              from commercial uses, including reversing alarms.
       (n)    Provide a more detailed acoustic assessment of vehicle movements and
              noise emissions on the site, particularly at night.
       (o)    Provide a more detailed explanation of the reasons for the height and length
              of the noise barrier along the Ferrells Road site boundary.
       (p)    Provide further information to support the noise mitigation measures listed
              for control of commercial uses noise emissions upon Ferrell Street receptors.
       (q)    Specify maximum sound power levels/acoustic performance requirements
              for all mechanical plant (including the carwash/vacuum facility) based upon
              the cumulative noise budget required to achieve compliance for commercial
              uses for Ferrell Street receptors and tourist park cabins and mobile
              accommodation.
       (r)    Provide a draft noise management plan that covers, as a minimum, authority,
              training, expectations, maintenance of noise mitigation measures, vehicle
              speed management on site, patron behaviour and noise control, and
              complaints.

Issue – Plans to Reflect Acoustic Recommendations
The proposal documents should reflect the recommendations of the Acoustic Assessment.

Information Required
40     Provide an updated town planning report and architectural drawings that include the
       recommendations of the acoustic report, with the architectural drawings to include
       noise barriers and a floor layout for the site manager’s building.

ENVIRONMENTAL HEALTH

Issue - Manifest Quantity Workplace
Service Station design details were not provided in proposal.

Information required
41     Provide details of how the Manifest Quantity Workplace (MQW) will comply with
       State interests (Workplace Health and Safety Queensland) for the design and
       operation of the site.

Issue – Environmental Protection
Further information is required to assess the service station and its storm water/spill
containment system in order to prevent or minimise environmental harm and demonstrate
compliance with the general environmental duty under the Environmental Protection Act
1994.

Information Required
42     Please provide detailed design information of the service station, including the
       following as a minimum:




                                                                                Page 9 of 12
Log in to download the original file

MCU14_0056 Information Request.pdf · 95 KB (small file)

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.