Council archive · source document
07/0387 - Submitted plans [As Published] · 142007.387
Plans and drawings: the text below has words only, no drawings.
oo
DRAWING SIZE - Ad
First Floor
Ground Floor
V
TG
Ed
- |
Ys
FWG
Basement Floor
Z
Temperature /Pressure
limiting valve
eS STACK DIAGRAM
so)
Hot water outlet
—
branch
HW.U.
Hot water temperature
control devices in
acoord AS3500.4.2
200 HW
200 CW
75 min
typical
To vented
~~
Cold expansion
valve, outlet
to drain
Union /
SHR
FWG
Line
stroiner
Pressure limiting
valve.
208 CW Supply
{~~ valve
WA
(min
fitting Pe /
vs
Non=retum
T
50¢ sofe_/”
waste.
(AS3500.4)
Sofe tray in eccordance with
AS35900.4 4.4 — O 4.5
T_WATER UNIT DETAIL
{<H><]
i Isolating valve
mount on wail
FIRST FLOOR PLAN
40V
DISCHARGE PIPE SIZE
FIXTURE
ON
vB
B
SHR
WC
SK
tT
FWG
40
40
40
100
50
65
65
Revision | Description Date
A. Re issued plans. 11.10.06.
8. Re issued plans. 16.04.07.
Mott 9/08/2008 4:34 Pu 10115-H1-H4.dwg
General Notes :
1. Hydraulic services shown are diagramatic only. Refer to architectural
drawings for locations of fixtures.
2 All Sonitory Hydraulics and Water Reticulation within the allotment
boundary to be in accordance with AS3500.
3. All work shall comply with the requirements of authorities having
prisdiction, after obtaining all necessary permits ond approvals.
4. The contractor is to confirm the position of all existing services as
indicated on these and associated plans prior to the commencing of
work.
5. Stormwater drainage pipes to 225¢ shall be Class SW uPVC HEAVY
(U.N.0.) pipe. Over 225¢ Concrete Rubber Ring Joint (RRu) Cless 3. All
pipes U.N.0. to be laid at a minimum grade of | in 100 U.N.O. Joins ore
to be constructed in accordance with the manufacturers requirements.
6. Sewers 100mm diom. uPVC DWV (U.N.O.) and Iaid at a minimum
grade of 1 in 60.
7. Water supply pipework below ground is to be ;
63mm diam. or less - High Density Type 50
Class 12 Polyethylene
8. All above ground and internal water supply pipework to be Type B
Copper.
9. Woter services are not permitted in ground slabs and all joins and
connections shall be made above the slab.
10. Fire Hydrants are to be installed are to be installed in accordance
with AS2419.1. Hose Reels ore to be installed in accordance with AS2441.
11. Clean—outs, Inspection openings and Closing cops situated in
vehicular or pedestrian pavements are to be fitted with either brass or
cast-iron covers.
12. Alt in-ground valves shall be in accordance in approved concrete
poth boxes.
13. All waste pipes and water services penetrating slabs to be wrapped
in an approved flexible joint joint wrapping.
14. The term 'SERVICE’ refers to the minimum internal pipe diometer
unless noted otherwise.
DEBUILD TA
CONSULTING
SC structural = Sivi
F > Gl
ABN 40 098 481 899
ENGINEERS
- geolechnical
LEGEND
8 Bath
CO Clean-Out HR
DP Rainwater Down—Pipe HWU
FP Frog Flop IC
FWG Floor Waste Gully lo
HC Hose Cock
HCB
36m Fire Hose Reel
Hot Water Unit
Inspection Chamber
Inspection Opening
Laundry Tub
House Connection Branch NRV
ORG
PLY
s¢
SHR
SK
Non~Return Valve TG
Overflow Relief Gully ¥
Pressure Limiting Valve VB
Stop Cock ve
Shower We
Sink WW
Test Gate
Vent
Vanity Basin
Vent Cow!
Water Closet
Washing Machine
KEY
UPVC Sewer, size grade and invert
level as noted
External Poly Water Service, size as noted Sy he
internat Cold Water service
Internal Hot Water service
Cal
=o
&—
—)
Water Meter.
levels os noted
Cold and Hot Water riser
riser locations and size.
— Fixture Unit loading.
Sonitary Stack number and Vent size
Stormwater pipe, size, grade and invert
Bey. - 30.01.05
18 DUKE STREET SUNSHINE BEACH QLD.4567
Ph (07) 5447 5544 Fax (07) 5447 2634
Title: Internal Hydraulics Arrangement
Project Lot 161 Orealla Cres
Sunrise Beach
Rev
Date: May 2006 Drg No.16115-H1
2408/2007 4:55:49 PM, Lit
See the original
The page text is free to read. Viewing or downloading an original file needs an account.
Log in to see the originalUsed in these records
07/0387 - Submitted plans [As Published]Related documentApplication case desk ↗
About this file
- File size
- 2.7 MB (large file)
- File type
No other editions are linked here.
Original file
Log in to download the original file
The download may take up to a minute.