07/0387 - Submitted plans [As Published] · 142007.387

of 31

Check the original when the exact wording matters.

Plans and drawings: the text below has words only, no drawings.

Log in to see the plans as drawn
oo

 

DRAWING SIZE - Ad

First Floor

 

Ground Floor
V

 

 

TG
Ed
- |

 

 

Ys

 

 

FWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Basement Floor

Z

 

 

 

 

 

Temperature /Pressure
limiting valve

eS STACK DIAGRAM
so)

Hot water outlet

—

branch

  

 

HW.U.

 

Hot water temperature
control devices in
acoord AS3500.4.2

200 HW

 

 

 

200 CW

         

75 min
typical

 

To vented

~~

 

 

 

 

 

 

 

 

 

Cold expansion
valve, outlet
to drain

Union /

 

 

 

 

 

 

 

 

 

 

 

 

 

SHR

FWG

 

 

 

 

 

 

 

 

 

 

 

Line
stroiner

Pressure limiting
valve.

208 CW Supply

 

 

 

 

 

 

 

 

{~~ valve

WA

(min

fitting Pe /
vs

Non=retum

 

T

 

 

 

 

50¢ sofe_/”

waste.

(AS3500.4)

 

Sofe tray in eccordance with
AS35900.4 4.4 — O 4.5

T_WATER UNIT DETAIL

{<H><]

i Isolating valve

mount on wail

FIRST FLOOR PLAN

 

40V

 

DISCHARGE PIPE SIZE

 

FIXTURE

ON

 

vB
B
SHR
WC
SK
tT
FWG

 

 

40
40
40
100
50
65
65

 

 

Revision | Description Date

 

A. Re issued plans. 11.10.06.

 

8. Re issued plans. 16.04.07.

 

 

 

 

 

Mott 9/08/2008 4:34 Pu 10115-H1-H4.dwg

General Notes :

1. Hydraulic services shown are diagramatic only. Refer to architectural
drawings for locations of fixtures.

2 All Sonitory Hydraulics and Water Reticulation within the allotment
boundary to be in accordance with AS3500.

3. All work shall comply with the requirements of authorities having
prisdiction, after obtaining all necessary permits ond approvals.

4. The contractor is to confirm the position of all existing services as
indicated on these and associated plans prior to the commencing of
work.

5. Stormwater drainage pipes to 225¢ shall be Class SW uPVC HEAVY
(U.N.0.) pipe. Over 225¢ Concrete Rubber Ring Joint (RRu) Cless 3. All
pipes U.N.0. to be laid at a minimum grade of | in 100 U.N.O. Joins ore
to be constructed in accordance with the manufacturers requirements.
6. Sewers 100mm diom. uPVC DWV (U.N.O.) and Iaid at a minimum
grade of 1 in 60.

7. Water supply pipework below ground is to be ;

63mm diam. or less - High Density Type 50

Class 12 Polyethylene

8. All above ground and internal water supply pipework to be Type B
Copper.

9. Woter services are not permitted in ground slabs and all joins and
connections shall be made above the slab.

10. Fire Hydrants are to be installed are to be installed in accordance
with AS2419.1. Hose Reels ore to be installed in accordance with AS2441.
11. Clean—outs, Inspection openings and Closing cops situated in
vehicular or pedestrian pavements are to be fitted with either brass or
cast-iron covers.

12. Alt in-ground valves shall be in accordance in approved concrete
poth boxes.

13. All waste pipes and water services penetrating slabs to be wrapped
in an approved flexible joint joint wrapping.

14. The term 'SERVICE’ refers to the minimum internal pipe diometer
unless noted otherwise.

 

  

 

DEBUILD TA
CONSULTING

SC structural = Sivi

F > Gl
ABN 40 098 481 899

ENGINEERS
- geolechnical

  

 

 

LEGEND

8 Bath
CO Clean-Out HR
DP Rainwater Down—Pipe HWU
FP Frog Flop IC
FWG Floor Waste Gully lo
HC Hose Cock

HCB
36m Fire Hose Reel
Hot Water Unit
Inspection Chamber
Inspection Opening
Laundry Tub

 

House Connection Branch NRV

ORG
PLY
s¢
SHR
SK

Non~Return Valve TG
Overflow Relief Gully ¥
Pressure Limiting Valve VB
Stop Cock ve
Shower We
Sink WW

Test Gate

Vent

Vanity Basin
Vent Cow!
Water Closet
Washing Machine

 

KEY

 

 

UPVC Sewer, size grade and invert

level as noted

External Poly Water Service, size as noted Sy he

internat Cold Water service

Internal Hot Water service

Cal

=o

&—
—)

Water Meter.

levels os noted
Cold and Hot Water riser
riser locations and size.

— Fixture Unit loading.

Sonitary Stack number and Vent size

Stormwater pipe, size, grade and invert

Bey. - 30.01.05

18 DUKE STREET SUNSHINE BEACH QLD.4567
Ph (07) 5447 5544 Fax (07) 5447 2634

 

Title: Internal Hydraulics Arrangement

 

Project Lot 161 Orealla Cres
Sunrise Beach

 

 

Rev

Date: May 2006 Drg No.16115-H1

 

 

 

2408/2007 4:55:49 PM, Lit

 

Used in these records

About this file

File size
2.7 MB (large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

07_0387 - Submitted plans [As Published].pdf · 2.7 MB (large file)