Flood Study




8                    Developed Case Results
8.1                  Peak Water Levels
The developed case peak water levels are shown in Appendix F. The resultant impact on peak water levels
for the local and regional flood events are also shown in Figures 22 to 35. The resultant minimum lot levels
are shown in Figure 13B.
J&K Hofmann Site
The 100 year ARI peak flood level (with climate change) around Precinct 3 Area H is approximately
3.01 mAHD. Therefore the minimum floor levels in this area are 3.51 mAHD.
The 100 year ARI peak flood level (with climate change) around the northern section of Precinct 3 Area I is
approximately 3.48 mAHD. Therefore the minimum floor levels in this area are 3.98 mAHD. The remainder
of Precinct I is well above the flood level of the tributary, even with the easement crossing in place.
The 100 year ARI peak flood level (with climate change) around Precinct 4 Area K is approximately 7.16
mAHD. Therefore the minimum floor levels in this area are 7.66 mAHD. For the proposed lot adjacent to
Hollett Road the 100 year ARI flood level (with climate change) is 7.53 mAHD, and so the minimum floor
level is 8.03 mAHD.
The 100 year ARI peak flood level (with climate change) around Precinct 4 Area L is a maximum of 5.40
mAHD. Therefore the minimum floor levels in this area are 5.90 mAHD Precinct 4 Area J is located well
above the flood level of the tributaries.
The 100 year ARI peak water level over the proposed internal road, running parallel Hollett Road is variable
but is approximately 7.39 mAHD at the crest, with a maximum depth of 40mm. The PMF peak depth is
approximately 220mm, which is considered trafficable. The dV product across the road in a PMF event is
approximately 0.33 m 2/s. The peak water levels immediately upstream of this crossing, i.e. within the Hollett
Road reserve, have been increased in major flood events. However, the increase is generally contained
within the road reserve and does not extend a significant distance upstream. As an alternate route with
improved flood immunity is proposed this is considered acceptable. This approach also allows the existing
vegetation within the road reserve to be maintained.
The 100 year ARI peak water level across the proposed easement crossing is 4.36m AHD, resulting in a
flood depth of 60mm, and so it is trafficable in a 100 year ARI event. It also has 10 year ARI immunity. This
crossing does not have PMF trafficability. This crossing could potentially improve flood access for the
neighbouring Lake Entrance Boulevard area. The peak water levels upstream of the easement crossing are
increased. This increase is contained within the site.
The water levels downstream of the easement are decreased by approximately 6mm in the 100 year ARI
event and 10mm in the 20 year ARI event. This decrease extends up to Lake Entrance Boulevard. In the 2
and 1 year ARI events, there are some small areas of increase of approximately 6mm downstream of the
easement, near the confluence with Eenie Creek. These increases are contained within the waterway area.
It should be noted that additional attenuation provided by the proposed rainwater tanks and bio-retention
basins is likely to reduce this impact.
The filling of the three lots within Precinct 3 Area I has not had a noticeable impact on peak flood levels in
this area.
Northbrook Site
The 100 year ARI peak flood level (with climate change) around Precinct 2 is approximately 2.80 mAHD.
Therefore the minimum floor levels in this area are 3.30 mAHD.
The 100 year ARI peak flood level (with climate change) within Lake Weyba is 2.72 mAHD. Therefore the
minimum floor level for lots adjacent to the lake (Precinct 1) is 3.22 mAHD.




Northbrook Corporation Pty Ltd                    Version 4                                  16 September 2013
Flood Study v4.doc                          Commercial in Confidence                                  Page 22

Used in these records

About this file

File size
37.1 MB (very large file)
File type
PDF

No other editions are linked here.

Original file

Log in to download the original file

Attachment 13- Amended Flood Study MCU12_0208.pdf · 37.1 MB (very large file)

The download may take a few minutes. On mobile data, it is best to wait for Wi-Fi.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.