PLANNING & ENVIRONMENT COMMITTEE MEETING AGENDA                            8 NOVEMBER 2016


    DURING CONSTRUCTION
          General
    17.   The developer must meet any costs to repair damage to any Council asset during
          construction, where damage is a result of the development works. Damage to assets
          must be repaired immediately where it creates a hazard to the community. In
          circumstances where the damage does not create a hazard to the community, it must
          be repaired immediately on completion of the works associated with the
          development.
    18.   All works must be supervised by a Registered Professional Engineer of Queensland
          (RPEQ) who is independent of the Developer and Principal Contractor, and they must
          certify that all works conform to the Operational Works permit. Where municipal
          works are involved, such confirmation must be submitted for the respective hold
          points prior to any site inspection by Council Officers.
    19.   All works must be constructed and work procedure undertaken in accordance with:
          a.   The approved plans and conditions detailed in this Decision Notice.
          b.   All relevant Noosa Council Planning Scheme Policies, standard drawings,
               standard specifications and guidelines, particularly PSP 5 – Engineering Design
               Standards – Roads, Drainage and Earthworks.
          c.   The latest version of the Healthy Waterways document “Water Sensitive Urban
               Design Technical Design Guidelines for South East Queensland” for all water
               quality devices to be constructed on site.
          Driveways
    20.   Driveway crossovers must be designed and constructed generally in accordance with
          the approved plans and in accordance with IPWEA standard drawing RS- 051 and
          must have levels and grades match the levels and the grades of the existing concrete
          footpath without posing trip hazard.
    21.   The following must be complied with during the construction of the required
          crossovers/driveways:
          a.   The driveway width must not exceed 6m at the front boundary line and 13m at
               the kerb line.
          b.   The driveway surfacing must consist of either an approved hot mixed asphaltic
               concrete or patterned/plain concrete and must have a slip resistant surface.
          c.   The driveway must be constructed so as not to concentrate stormwater runoff
               or ponding onto other properties and/or the road verge.
          d.   For public safety, the finish levels of crossover must ensure smooth transition to
               existing surfaces such as the road grassed verge and existing concrete
               pathway.
          e.   Where applicable, underground service conduits for water supply, electricity
               and any other services must be provided as part of the access driveway works.
          f.   Have a minimum clearance of 1.0m from any existing power poles, streetlights
               or other signage.
          g.   Have a minimum clearance of 500mm from any Unitywater/Telstra asset,
               unless a written approval is obtained from Unitywater/Telstra and submitted to
               Council.




                                                                                  Page 45 of 70
Log in to download the original file

2016-11-08 S&O Agenda - Item 1, Attachment 1 - Annual Report 2015-16(PDF, 7MB).pdf · 7.6 MB (large file)

Large file: the download may take up to a minute.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.