            Including amendments to 3 July 2017




                                                                 Specific Outcomes                            Acceptable solutions (if accepted
The Noosa Plan



                                                                                                           development subject to requirements)
                                                                                                          Probable solutions (if code assessment)
                                                  services and utilities appropriate to its setting.    water or sewerage service area, appropriate
                                                                                                        connection is provided to reticulated sewerage,
                                                                                                        water supply and stormwater drainage.
                                                  Electricity supply infrastructure
                                                  O7 Uses and works maintain an adequate                S7.1 Buildings and structures (including
                                                  safe distance from electrical infrastructure          swimming pools, sheds, tennis courts or
                                                  including substations, overhead powerlines,           outbuildings) are not constructed under
                                                  power poles and transformers.                         overhead electricity transmission lines, or within
                                                                                                        electricity easements.
                                                  Water Supply Infrastructure
                                                  O8 Existing water supply infrastructure,              S8.1 Buildings and structures are setback a
                                                  including pipeline corridor, is protected from        minimum of 20m from a water supply pipeline
                                                  incompatible development to ensure the safety         as shown on Overlay Map OM3.5.
                                                  and reliability of water supply network.
                                                  Gas Pipeline                                          S9.1 No new buildings for the purpose of
                                                  O9 Adequate separation is provided between            Residential Uses (except for a Detached house
                                                  the new building works and the gas pipeline           or class 10 building), Education uses, Wellbeing
                                                  shown on Overlay Maps OM3.5 or OM5.5;                 uses or Retail business uses are within 200m of
                                                                                                        the gas pipeline shown on Overlay Maps OM3.5
                                                                                                        or OM5.5;
                                                  AND
                                                                                                        AND

                                                  O10 Building works are constructed and                S10.1Any building works for the purpose of
                                                  operated to avoid damaging or adversely               storage of flammable, explosive or other
                                                  affecting the operation of the pipeline and the       hazardous materials are not within 200m of the
                                                  supply of gas.                                        gas pipeline shown on Overlay Maps OM3.5 or
                                                                                                        OM5.5.

                                                                                                        S10.2 No solution provided (no requirement for
                                                                                                        accepted development development).
                                                  Steep Slopes and Landslide hazard areas
                                                  O11 Detached houses, Multiple housing                 S119.1 If on premises identified as a Landslide
                                                  Type 2 Duplex, Ancillary dwelling units, and          Hazard Area on Overlay Maps OM1.3–9.3, or
                                                  associated uses are sited or constructed to           on steep slopes the use does not–
                                                  maintain the safety of people and property from       a) involve the removal of vegetation other than
                                                  the risk of landslide.                                    grass from use areas; or
                                                                                                        b) involve excavating or filling of more than
                                                                                                            50m3 of material (other than placement of
                                                                                                            topsoil not exceeding 100mm in depth
                                                                                                            relative to natural ground level; or
                                                                                                        c) involve cut or fill with a depth of more than
                                                                                                            2m relative to natural ground level; or
                                                                                                        d) redirect or impede water flows in an
                                                                                                            existing watercourse or stormwater drain;
                                                                                                            or
                                                                                                        e) involve construction of an on-site effluent
                                                                                                            disposal system;
                                                                                                        OR

                                                                                                        S119.2 A site specific geo-technical report
                                                                                                        prepared by a registered professional engineer
                                                                                                        either—
                                                                                                        a) certifies that the site is not at risk from
                                                                                                             landslide emanating from the site or from


                                                                                                    14-60
                                                                                  Detached House CodeLow Density Housing Code
Log in to download the original file

2017-11-07 P&E Committee - Attachment 1 to Item 1 - Amendments for Multiple Housing Type 2 Duplex & Minor Corrections(PDF, 9MB).pdf · 9.9 MB (large file)

The download may take up to a minute.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.