4.2         Car Park Layout
Table 4-3 identifies the characteristics of the proposed parking area with respect to the Council
requirements. The last column identifies the compliance of each design aspect.

Table 4-3: Parking Design Requirements

  Design Aspect                  Minimum AS2890.1           Proposed Provision    Compliance
                                 Standard
  Parking space length:
       − Standard bay            5.4m                       5.4m                  Compliant
  Parking space width:
       − Staff                   2.4m                       2.6m                  Compliant
       − Public                  2.6m                       2.6m
        − Vallet                 2.4m                       2.6m
        − PWD                    2.4m + 2.4m ‘Shared        2.4m + 2.4m ‘Shared
                                 Area’                      Area’
  Aisle Width:
       − Parking aisle           5.8m                       6.5m                  Compliant
       − Circulation             5.8m                       6.0-6.5m
          aisle/ramp
  Parking envelope               Space 0.3m clear of        Space 0.3m clear of   Compliant
  clearance – space              wall                       wall
  adjacent to wall
  Maximum Gradient:
      − PWD parking              1:40 (2.5%)                1:40 (2.5%)           Compliant
      − Parking bay              1:20 (5.0%)                1:20 (5.0%)
      − Parking aisle            1:16 (6.25%)               1:16 (6.25%)
      − Ramp                     1:5 (20%)                  1 in 8 (12.5%)


  Height Clearance
      − General Min.             2.2m (2.3m PWD)            2.3m                  Compliant




The proposed car park layout complies with Council’s / Australian Standard requirement and is therefore
considered suitable.




Site: 3-7 Serenity Close, Noosa Heads – Proposed Resort Complex                                           16
Reference: 22BRT022 RP01_1
Log in to download the original file

Traffic Report.pdf · 24.2 MB (very large file)

Very large file: the download may take a few minutes. If you are on mobile data, it is best to wait until you are on Wi-Fi.

Searchable page text hides email addresses. Original files are unchanged and may show email addresses.

The supporting record

Open full page ↗

Source document

Analyse documents ↗Open full page ↗

My Comparisons

Choose two to four records of the same kind. Drag using a handle or use the “Compare” buttons.

Your selected records are saved in this browser for your account. Results use the filters on the page where you choose “Compare selected”.